Validation of real-time continuous perfusion measurement

被引:17
作者
Martin, GT [1 ]
Bowman, HF
机构
[1] Thermal Technol Inc, Cambridge, MA USA
[2] Harvard MIT Div Hlth Sci & Technol, Cambridge, MA USA
关键词
blood flow; perfusion; thermal diffusion probe; microspheres; rabbits;
D O I
10.1007/BF02347053
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Perfusion, the rate at which blood in tissue is replenished at the capillary level, is a primary factor in the transport of heat, drugs, oxygen and nutrients. While there have been many measurement techniques proposed, most do not lend themselves to routine, continuous and real-time use. A minimally invasive probe, called the thermal diffusion probe (TDP), which uses a self-heated thermistor to measure absolute perfusion continuously and in real time, was validated at low flows with the microsphere technique. In 27 rabbits, simultaneous TDP measurements were made in liver from 0 to 60 ml min(-1) 100 g(-1). The TDP perfusion correlated well with the microspheres (R-2 = 0.898) and the agreement between techniques is very good with a slope close to unity (0.921) and an intercept close to zero (0.566 ml min(-1) 100 g(-1)). Variability between the two techniques was primarily due to the sampling error from the microsphere 'snap shot' of periodic blood flow when compared with the continuous TDP perfusion measurement. The ability to quantify local perfusion continuously and in real time may have a profound impact on patient management in a number of clinical areas such as organ transplantation, neurosurgery, oncology and others, in which quantitative knowledge of perfusion is of value.
引用
收藏
页码:319 / 325
页数:7
相关论文
共 14 条
[1]   Perioperative monitoring of the cortical microcirculation in clinical renal transplantation by thermodiffusion [J].
Angelescu, M ;
Bredt, M ;
Kraus, T ;
Weber, C ;
Wiesel, M ;
Klar, E .
TRANSPLANTATION PROCEEDINGS, 1997, 29 (07) :2790-2792
[2]  
Bouma G J, 1995, New Horiz, V3, P384
[3]  
BOWMAN HF, 1984, HEAT TRANSFER MED BI, V1, P193
[4]  
Choksey MS, 1996, CEREBROVAS BRAIN MET, V8, P230
[5]  
Dewhirst Mark W., 1993, P3
[6]  
KALR E, 1996, TRANSPLANTATION INT, V9, pS140
[7]   Early assessment of reperfusion injury by intraoperative quantification of hepatic microcirculation in patients [J].
Klar, E ;
Bredt, M ;
Kraus, T ;
Angelescu, M ;
Mehrabi, A ;
Senninger, N ;
Otto, G ;
Herfarth, C .
TRANSPLANTATION PROCEEDINGS, 1997, 29 (1-2) :362-363
[9]   TUMOR BLOOD-FLOW - MEASUREMENT AND MANIPULATION FOR THERAPEUTIC GAIN [J].
SAGAR, SM ;
KLASSEN, GA ;
BARCLAY, KD ;
ALDRICH, JE .
CANCER TREATMENT REVIEWS, 1993, 19 (04) :299-349
[10]  
SALVANT JB, 1993, NEUROSURGERY, V33, P387