Use of semi-permeable membrane devices and solid-phase extraction for the wide-range screening of microcontaminants in surface water by GC-AED/MS

被引:31
作者
van Stee, LLP [1 ]
Leonards, PEG
van Loon, WMGM
Hendriks, AJ
Maas, JL
Struijs, J
Brinkman, UAT
机构
[1] Free Univ Amsterdam, Dept Analyt Chem & Appl Spectroscopy, ACAS, NL-1081 HV Amsterdam, Netherlands
[2] RIVO BV, Netherlands Inst Fisheries Res, Ijmuiden, Netherlands
[3] RIKZ, Natl Inst Coastal & Marine Management, Haren, Netherlands
[4] Inst Inland Water Management & Waste Water Treatm, Lelystad, Netherlands
[5] Natl Inst Publ Hlth & Environm, RIVM, Bilthoven, Netherlands
关键词
solid-phase extraction; semi-permeable membrane devices; atomic emission detection; gas chromatography; mass spectrometry; organic pollutants; surface water; contaminant identification;
D O I
10.1016/S0043-1354(02)00177-X
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
An automated GC-MS-based screening method was developed for over 400 industrial, agrochemical and household chemicals. Extracted ion chromatograms were used and the method was aimed at creating a minimum number of false positives. The compound polarity range usually associated with solid-phase extraction was extended to include very apolar, bioaccumulative, compounds by using the complementary semi-permeable membrane device technique. Real-life samples were taken at four locations in the main Dutch river systems and one in an agricultural area. Some 150 compounds were detected in the low-ng/l to low-mug/l range. Next to the target compounds, several brominated and chlorinated non-target compounds were detected by means of GC with atomic emission detection and tentatively identified using mass spectral library searching. (C) 2002 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:4455 / 4470
页数:16
相关论文
共 29 条
[1]   Evaluation of the oral subchronic toxicity of HHCB (1,3,4,6,7,8-hexahydro-4,6,6,7,8,8-hexamethylcyclopenta-γ-2-benzopyran) in the rat [J].
Api, AM ;
Ford, RA .
TOXICOLOGY LETTERS, 1999, 111 (1-2) :143-149
[2]   Results of non target screening of lipophilic organic pollutants in the German Bight II:: Polycyclic musk fragrances [J].
Bester, K ;
Hühnerfuss, H ;
Lange, W ;
Rimkus, GG ;
Theobald, N .
WATER RESEARCH, 1998, 32 (06) :1857-1863
[3]   Calibrating the uptake kinetics of semipermeable membrane devices using exposure standards [J].
Booij, K ;
Sleiderink, HM ;
Smedes, F .
ENVIRONMENTAL TOXICOLOGY AND CHEMISTRY, 1998, 17 (07) :1236-1245
[4]  
Brunn H, 1997, ERNAHRUNGS-UMSCHAU, V44, P4
[5]   Developmental toxicity studies of four fragrances in rats [J].
Christian, MS ;
Parker, RM ;
Hoberman, AM ;
Diener, RM ;
Api, AM .
TOXICOLOGY LETTERS, 1999, 111 (1-2) :169-174
[6]  
COLLOMBON M, 1997, 607042008 RIVM
[7]  
DALLUGE JJ, 2001, IN PRESS J CHROMAT A
[8]  
Draisci R, 1999, IND ALIMENT-ITALY, V38, P374
[9]  
Ford RA, 1998, DEUT LEBENSM-RUNDSCH, V94, P268
[10]  
Franke S, 1999, CHIRALITY, V11, P795, DOI 10.1002/(SICI)1520-636X(1999)11:10<795::AID-CHIR10>3.0.CO