Dosimetry inside MIR station using a silicon detector telescope (DOSTEL)

被引:31
作者
Beaujean, R [1 ]
Kopp, J
Burmeister, S
Peterson, F
Reitz, G
机构
[1] Univ Kiel, Inst Expt & Angew Phys, D-24109 Kiel, Germany
[2] DLR, Inst Luft & Raumfahrtmed Strahlenbiol, D-51140 Cologne, Germany
关键词
space flights; active dosimetry; silicon detectors; dose equivalent; LET-spectra;
D O I
10.1016/S1350-4487(02)00074-4
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
The dosimetry telescope (DOSTEL)was flown on the MIR orbital station during October 1997-January 1998. The mission average contributions to the absorbed dose rates (in water) were 126 +/- 4 muGy/d and 121 +/- 13 muGy/d for the GCR and the SAA component, respectively. The mean quality factors (ICRP60) deduced from the LET-spectra are 3.5 +/- 0.2 (GCR) and 1.3 +/- 0.1 (SAA). Separate LET spectra and temporal variations of the absorbed dose rates and of the mean quality factors are presented for these two radiation components as well as for solar energetic particles of the November 6, 1997 event. (C) 2002 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:433 / 438
页数:6
相关论文
共 12 条
[1]  
ATWELL W, 2001, COMMUNICATION
[2]   Measurements of the linear energy transfer spectra on the Mir orbital station and comparison with radiation transport models [J].
Badhwar, GD ;
Konradi, A ;
Atwell, W ;
Golightly, MJ ;
Cucinotta, FA ;
Wilson, JW ;
Petrov, VM ;
Tchernykh, IV ;
Shurshakov, VA ;
Lobakov, AP .
RADIATION MEASUREMENTS, 1996, 26 (02) :147-&
[3]  
BADHWAR GD, 1998, COMMUNICATION
[4]  
BADHWAR GD, 1997, RADIAT RES, V148, P3
[5]   HZE-DOSIMETRY IN-SPACE - MEASUREMENTS AND CALCULATIONS [J].
BEAUJEAN, R ;
KOPP, J ;
LEICHER, M .
RADIATION MEASUREMENTS, 1995, 25 (1-4) :423-428
[6]   Active dosimetry on recent space flights [J].
Beaujean, R ;
Kopp, J ;
Reitz, G .
RADIATION PROTECTION DOSIMETRY, 1999, 85 (1-4) :223-226
[7]   Recent European measurements inside Biorack [J].
Beaujean, R ;
Reitz, G ;
Kopp, J .
MUTATION RESEARCH-FUNDAMENTAL AND MOLECULAR MECHANISMS OF MUTAGENESIS, 1999, 430 (02) :183-189
[8]   Measurements of LET-distribution, dose equivalent and quality factor with the RRMD-III on the Space Shuttle Missions STS-84,-89 and-91 [J].
Doke, T ;
Hayashi, T ;
Kikuchi, J ;
Sakaguchi, T ;
Terasawa, K ;
Yoshihira, E ;
Nagaoka, S ;
Nakano, T ;
Takahashi, S .
RADIATION MEASUREMENTS, 2001, 33 (03) :373-387
[9]  
Doke T, 2001, RADIAT RES, V156, P310, DOI 10.1667/0033-7587(2001)156[0310:COLDMI]2.0.CO
[10]  
2