COMPARISON OF HAND DYNAMOMETERS IN ELDERLY PEOPLE

被引:59
作者
Guerra, R. S. [1 ]
Amaral, T. F. [1 ,2 ]
机构
[1] Univ Porto, Fac Ciencias Nutr & Alimentacao, P-4200465 Oporto, Portugal
[2] Univ Porto, Inst Engn Mecan, UISPA, P-4200465 Oporto, Portugal
关键词
Hand grip strength; dynamometers; elderly; Mini Nutritional Assessment; MINI NUTRITIONAL ASSESSMENT; OF-THE-LITERATURE; GRIP STRENGTH; JAMAR DYNAMOMETER; TELL US; INSTRUMENTS; MALNUTRITION; ADULTS; RISK; MNA;
D O I
10.1007/s12603-009-0250-3
中图分类号
R592 [老年病学]; C [社会科学总论];
学科分类号
03 ; 0303 ; 100203 ;
摘要
Objective: Some dynamometers previously tested in healthy adults showed variable degrees of practicality, weight and ergonomics. More practical models could also be used as a more suitable tool in gerontological field and clinical studies. The purpose of the present study was to evaluate the reliability of the measurements and the performance of hand grip strength dynamometers in the elderly. Study design: Cross-sectional study. Setting: A retirement home and a social day care centre for old people in Porto, Portugal. Participants and measurements: The accuracy of four static grip strength dynamometers (Smedlay's (R) Hand, Sammons Preston Rolyan (R) Bulb, Eisenhut (R) and the Jamar (R) Hydraulic Hand) was first tested in laboratory. The grip strength of fifty-five elderly individuals 65-99 years was measured with the four dynamometers and the Jamar (R) Hydraulic Hand which was used as the comparison dynamometer. Results: The accuracy of the four dynamometers measurements compared to known forces was excellent (r > 0.96). A strong association between the measurements obtained by the Jamar (R) Hydraulic and the other instruments evaluated was found (r > 0.77) but significant differences between the mean hand grip strength values evaluated with the Jamar (R) Hydraulic and each one of the other dynamometers were found. The Bland and Altman plots confirmed that none of the three dynamometers reflects a good agreement with the Jamar (R) Hydraulic. Conclusion: All four dynamometers showed excellent results regarding their laboratory tested accuracy. However, their application among elderly people rendered very different results. The Smedlay's (R) results' were closer to the Jamar (R) Hydraulic, though none of these three dynamometers produced comparable results to the Jamar (R) Hydraulic.
引用
收藏
页码:907 / 912
页数:6
相关论文
共 37 条
  • [1] Normative values for isometric muscle force measurements obtained with hand-held dynamometers
    Andrews, AW
    Thomas, MW
    Bohannon, RW
    [J]. PHYSICAL THERAPY, 1996, 76 (03): : 248 - 259
  • [2] [Anonymous], 2001, DICT EPIDEMIOLOGY
  • [3] [Anonymous], 1992, GRIP STRENGTH
  • [4] GRIP STRENGTH TESTING USING THE BTE WORK SIMULATOR AND THE JAMAR DYNAMOMETER - A COMPARATIVE-STUDY
    BEATON, DE
    ODRISCOLL, SW
    RICHARDS, RR
    [J]. JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1995, 20A (02): : 293 - 298
  • [5] Bellace J V, 2000, J Hand Ther, V13, P46
  • [6] STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
    BLAND, JM
    ALTMAN, DG
    [J]. LANCET, 1986, 1 (8476) : 307 - 310
  • [7] Bohannon Richard W, 2008, J Geriatr Phys Ther, V31, P3
  • [8] Bohannon Richard W., 2006, Physiotherapy Theory and Practice, V22, P219, DOI 10.1080/09593980600822875
  • [9] Parallel comparison of grip strength measures obtained with a MicroFET 4 and a jamar dynamometer
    Bohannon, RW
    [J]. PERCEPTUAL AND MOTOR SKILLS, 2005, 100 (03) : 795 - 798
  • [10] Brown AD, 2000, J MANAGE STUD, V37, P45