Inverse finite element characterization of soft tissues

被引:158
作者
Kauer, M [1 ]
Vuskovic, V
Dual, J
Szekely, G
Bajka, M
机构
[1] Swiss Fed Inst Technol, Ctr Mech, CH-8092 Zurich, Switzerland
[2] Swiss Fed Inst Technol, Inst Robot, CH-8092 Zurich, Switzerland
[3] Swiss Fed Inst Technol, Comp Vis Grp, CH-8092 Zurich, Switzerland
[4] Univ Hosp, Dept Gynaecol, CH-8091 Zurich, Switzerland
关键词
soft tissues; inverse finite element; in vivo; aspiration; viscoelastic;
D O I
10.1016/S1361-8415(02)00085-3
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
In this work a tissue aspiration method for the in vivo determination of biological soft tissue material parameters is presented. An explicit axisymmetric finite element simulation of the aspiration experiment is used together with a Levenberg-Marquardt algorithm to estimate the material model parameters in an inverse parameter determination process. An optimal fit of the simulated experiment and the real experiment is sought with the parameter estimation algorithm. Soft biological tissue is modelled as a viscoelastic, non-linear, nearly incompressible, isotropic continuum. Viscoelasticity is accounted for by a quasi-linear formulation. The aspiration method is validated experimentally with a synthetic material. In vivo (intra-operatively during surgical interventions) and ex vivo experiments were performed on human uteri. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:275 / 287
页数:13
相关论文
共 27 条
  • [1] [Anonymous], 1970, STRENGTH BIOL MAT
  • [2] Baur C, 1998, ST HEAL T, V50, P110
  • [3] CARTER FJ, IN PRESS MED IMAGE A
  • [4] Real-time elastic deformations of soft tissues for surgery simulation
    Cotin, S
    Delingette, H
    Ayache, N
    [J]. IEEE TRANSACTIONS ON VISUALIZATION AND COMPUTER GRAPHICS, 1999, 5 (01) : 62 - 73
  • [5] DIGIOIA AM, 2000, OPERATIVE TECHNIQUES, V10
  • [6] Material characterization of the pig kidney in relation with the biomechanical analysis of renal trauma
    Farshad, M
    Barbezat, M
    Flüeler, P
    Schmidlin, F
    Graber, P
    Niederer, P
    [J]. JOURNAL OF BIOMECHANICS, 1999, 32 (04) : 417 - 425
  • [7] Fornefett M., 1999, Proceedings. 1999 IEEE Computer Society Conference on Computer Vision and Pattern Recognition (Cat. No PR00149), P402, DOI 10.1109/CVPR.1999.786970
  • [8] MAGNETIC-RESONANCE-IMAGING TECHNIQUES FOR DETECTION OF ELASTICITY VARIATION
    FOWLKES, JB
    EMELIANOV, SY
    PIPE, JG
    SKOVORODA, AR
    CARSON, PL
    ADLER, RS
    SARVAZYAN, AP
    [J]. MEDICAL PHYSICS, 1995, 22 (11) : 1771 - 1778
  • [9] Gibson S. F. F., 1997, Proceedings 1997 Symposium on Interactive 3D Graphics, P149, DOI 10.1145/253284.253324
  • [10] Measurement of intraoperative brain surface deformation under a craniotomy
    Hill, DLG
    Maurer, CR
    Maciunas, RJ
    Barwise, JA
    Fitzpatrick, JM
    Wang, MY
    [J]. NEUROSURGERY, 1998, 43 (03) : 514 - 526