Indirect determination of alkaline phosphatase based on the amperometric detection of indigo carmine at a screen-printed electrode in a flow system

被引:14
作者
Díaz-González, M [1 ]
Fernández-Sánchez, C [1 ]
Costa-García, A [1 ]
机构
[1] Univ Oviedo, Dept Quim Fis & Analit, E-33006 Oviedo, Asturias, Spain
关键词
D O I
10.2116/analsci.18.1209
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Amperometric analysis of indigo carmine at a bare screen-printed electrode placed in an FIA system is reported. This compound is easily detected at a potential of -0.3 V (vs. Ag pseudo-reference electrode) without observing any fouling of the electrode surface, thus allowing the repetitive use of the same electrode in a reproducible manner (coefficients of variation down to 7% for more than 20 consecutive determinations). A linear range of three orders of magnitude and a limit of detection in the sub-micromolar range were attained for this molecule. Based on these studies, indirect amperometric measurements of alkaline phosphatase (ALP) activity in solution were easily carried out using 3-indoxyl phosphate substrate. Its hydrolysis catalyzed by ALP gave rise to indigo product. This product is insoluble in aqueous solutions but it was easily converted into its soluble parent compound, indigo carmine, by addition of fuming sulfuric acid to the reaction media. Using this approach. we achieved a linear range of more than one order of magnitude and a limit of detection of 1 U/l ALP. for an enzymatic reaction time of 60 min.
引用
收藏
页码:1209 / 1213
页数:5
相关论文
共 27 条
[1]   MASS-PRODUCTION OF BIOSENSORS [J].
ALVAREZICAZA, M ;
BILITEWSKI, U .
ANALYTICAL CHEMISTRY, 1993, 65 (11) :A525-A533
[2]   Subfemtomolar determination of alkaline phosphatase at a disposable screen-printed electrode modified with a perfluorosulfonated ionomer film [J].
Bagel, O ;
Limoges, B ;
Schollhorn, B ;
Degrand, C .
ANALYTICAL CHEMISTRY, 1997, 69 (22) :4688-4694
[3]   Zeptomole-detecting biosensor for alkaline phosphatase in an electrochemical immunoassay for 2,4-dichlorophenoxyacetic acid [J].
Bauer, CG ;
Eremenko, AV ;
EhrentreichForster, E ;
Bier, FF ;
Makower, A ;
Halsall, HB ;
Heineman, WR ;
Scheller, FW .
ANALYTICAL CHEMISTRY, 1996, 68 (15) :2453-2458
[4]  
Bengoechea Alvarez M. Jose, 2001, Analytica Chimica Acta, V442, P55
[5]  
Díaz-González M, 2002, ELECTROANAL, V14, P665, DOI 10.1002/1521-4109(200205)14:10<665::AID-ELAN665>3.0.CO
[6]  
2-C
[7]  
Fernandez Bobes Cecilia, 2001, Electroanalysis, V13, P559
[8]  
Fernández-Abedul MT, 2001, RRD PURE APPL ANALYT, V3, P115
[9]   Competitive enzyme immunosensor developed on a renewable carbon paste electrode support [J].
Fernández-Sánchez, C ;
Costa-García, A .
ANALYTICA CHIMICA ACTA, 1999, 402 (1-2) :119-127
[10]   Voltammetric studies of indigo adsorbed on pre-treated carbon paste electrodes [J].
Fernández-Sánchez, C ;
Costa-García, A .
ELECTROCHEMISTRY COMMUNICATIONS, 2000, 2 (11) :776-781