Sensory characterization of emissions from materials

被引:24
作者
Knudsen, HN [1 ]
Clausen, G [1 ]
Fanger, PO [1 ]
机构
[1] DANISH BLDG RES INST,DK-2970 HORSHOLM,DENMARK
来源
INDOOR AIR-INTERNATIONAL JOURNAL OF INDOOR AIR QUALITY AND CLIMATE | 1997年 / 7卷 / 02期
关键词
emission testing; indoor air quality; material characterization; perceived air quality; sensory pollution load; test chamber;
D O I
10.1111/j.1600-0668.1997.t01-2-00004.x
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The exposure-response relationship between the concentration of air pollutants and perceived air quality was studied for eight materials often found indoors and for a mixture of three of the materials. Samples of the materials were placed in a ventilated test chamber. The exhaust air from the test chamber was diluted with different rates of unpolluted air to obtain five different concentrations of polluted air. A sensory panel assessed the perceived quality of the five concentrations of polluted air. The exposure-response relationship differed between the materials and also from the corresponding relationship for human bioeffluents. The exposure-response relationships can be described by straight lines in a log-probit plot and be defined by two constants characteristic for each material. Determination of the two constants characterizing each material requires sensory assessments at least at two pollution concentrations. The sensory pollution load for a material may change with the pollution concentration in the air. The use df a simple measurement method based on a dilution system connected to a ventilated small-scale test chamber is proposed to characterize the emissions from materials in sensory and chemical terms. (C) Indoor Air (1997).
引用
收藏
页码:107 / 115
页数:9
相关论文
共 21 条
[1]  
ALBRECHTSEN O, 1988, P HLTH BUILD 88 STOC, V3, P25
[2]  
*ASHRAE, 1989, 621989 ASHRAE
[3]   INDIVIDUAL PSYCHOPHYSICAL FUNCTIONS FOR 28 ODORANTS [J].
BERGLUND, B ;
BERGLUND, U ;
EKMAN, G ;
ENGEN, T .
PERCEPTION & PSYCHOPHYSICS, 1971, 9 (3B) :379-&
[4]  
BLUYSSEN P, 1989, P CLIMA 2000 SAR, V3, P25
[5]   VENTILATION REQUIREMENTS IN BUILDINGS .1. CONTROL OF OCCUPANCY ODOR AND TOBACCO-SMOKE ODOR [J].
CAIN, WS ;
LEADERER, BP ;
ISSEROFF, R ;
BERGLUND, LG ;
HUEY, RJ ;
LIPSITT, ED ;
PERLMAN, D .
ATMOSPHERIC ENVIRONMENT, 1983, 17 (06) :1183-1197
[6]   ODOR INTENSITY . DIFFERENCES IN EXPONENT OF PSYCHOPHYSICAL FUNCTION [J].
CAIN, WS .
PERCEPTION & PSYCHOPHYSICS, 1969, 6 (6A) :349-&
[7]  
*DIN, 1983, DIN 1946 2
[8]  
*ECA, 1991, 8 ECA
[9]  
ECA Guidelines for ventilation requirements in buildings, 1992, 11 ECA
[10]  
Fanger P.O., 1983, P ENG FDN C MAN ATM, P45