This work investigates the general problem of phase unwrapping for arbitrary N-dimensional phase maps. A cost function-based approach is outlined that leads to an integer programming problem. To solve this problem, a best-pair-first region merging approach is adopted as the optimization method. The algorithm was implemented and tested with 3D MRI medical data for venogram studies, as well as for fMRI applications in EPI unwarping and rapid, automated shimming. (C) 2003 Wiley-Liss, Inc.
引用
收藏
页码:193 / 197
页数:5
相关论文
共 21 条
[1]   A fast implementation of the minimum spanning tree method for phase unwrapping [J].
An, L ;
Xiang, QS ;
Chavez, S .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2000, 19 (08) :805-808
[2]   CORRECTION OF PHASE WRAPPING IN MAGNETIC-RESONANCE IMAGING [J].
AXEL, L ;
MORTON, D .
MEDICAL PHYSICS, 1989, 16 (02) :284-287
[3]   Two-dimensional phase unwrapping with use of statistical models for cost functions in nonlinear optimization [J].
Chen, CW ;
Zebker, HA .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2001, 18 (02) :338-351
[4]   Two-dimensional phase unwrapping using a minimum spanning tree algorithm [J].
Ching, Neng H. ;
Rosenfeld, Dov ;
Braun, Michael .
IEEE TRANSACTIONS ON IMAGE PROCESSING, 1992, 1 (03) :355-365
[5]   New robust 3-D phase unwrapping algorithms: Application to magnetic field mapping and undistorting echoplanar images [J].
Cusack, R ;
Papadakis, N .
NEUROIMAGE, 2002, 16 (03) :754-764
[6]   3-POINT DIXON TECHNIQUE FOR TRUE WATER FAT DECOMPOSITION WITH BO INHOMOGENEITY CORRECTION [J].
GLOVER, GH ;
SCHNEIDER, E .
MAGNETIC RESONANCE IN MEDICINE, 1991, 18 (02) :371-383
[7]   Interferometric data analysis based on Markov nonlinear filtering methodology [J].
Gurov, IP ;
Sheynihovich, DV .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2000, 17 (01) :21-27
[8]   A NEW 2-DIMENSIONAL PHASE UNWRAPPING ALGORITHM FOR MRI IMAGES [J].
HEDLEY, M ;
ROSENFELD, D .
MAGNETIC RESONANCE IN MEDICINE, 1992, 24 (01) :177-181
[9]  
Herment A, 2000, MAGN RESON MED, V44, P122, DOI 10.1002/1522-2594(200007)44:1<122::AID-MRM18>3.0.CO
[10]  
2-C