Comparison of arterial elasticity measured in left and right arms using the HDI/Pulsewave ™ CR-2000 Research System

被引:7
作者
Alavi, HB
Prisant, LM
Jupin, D
Oracion, A
机构
[1] Med Coll Georgia, Hypertens Unit, Augusta, GA 30912 USA
[2] Med Coll Georgia, Off Biostat, Augusta, GA 30912 USA
关键词
arterial elasticity; repeatability; diagnosis; blood pressure measurement; non-invasive measurement;
D O I
10.1097/00126097-200210000-00005
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Background Arterial elasticity is implicated as a risk factor for or a marker of cardiovascular disease. Current advances in non-invasive devices have now made it possible to measure arterial elasticity in an ambulatory setting. Objective The aim of this study was to determine whether there is a difference in blood pressure and arterial elasticity measured in the right and the left arms. Methods Simultaneous measurements were performed with two HDI/Pulsewave CR-2000 Research CardioVascular Profiling Systems. The manufacturer recommends placing the blood pressure cuff on the left upper arm and the sensor on the skin overlying the right radial artery. We followed the manufacturer's recommendations and also placed both the cuff and the sensor on the same arm. Simultaneous measurements were made on both arms with both machines. The average of three measurements was used for each combination. Systolic and diastolic blood pressure, and large-artery and small-artery elasticity indices, were determined for each subject and used in the analysis. Results The subjects were 11 males and 9 females between 22 and 46 (33.5 +/- 7.4 years) years of age. There was no significant difference in the average difference for each test combination. Conclusion Thus, when using the HDI/Pulsewave CR-2000 Research CardioVascular Profiling System, the blood pressure cuff and the sensor can be placed on either the same arm or opposite arms. Blood Press (C) 2002 Lippincott Williams Wilkins.
引用
收藏
页码:277 / 280
页数:4
相关论文
共 4 条
[1]  
Glasser SP, 1997, AM J HYPERTENS, V10, P1175
[2]   Arterial elasticity among normotensive subjects and treated and untreated hypertensive subjects [J].
Prisant, LM ;
Resnick, LM ;
Hollenberg, SM .
BLOOD PRESSURE MONITORING, 2001, 6 (05) :233-237
[3]   Assessment of sequential same arm agreement of blood pressure measurements by a CVProfilor™ DO-2020 versus Baumanometer® mercury sphygmomanometer [J].
Prisant, LM ;
Resnick, LM ;
Hollenberg, SM .
BLOOD PRESSURE MONITORING, 2001, 6 (03) :149-152
[4]   ARTERIAL COMPLIANCE IN HYPERTENSION [J].
RANDALL, OS ;
ESLER, MD ;
CALFEE, RV ;
BULLOCH, GF ;
MAISEL, AS ;
CULP, B ;
OROURKE ;
WIKSTRAND ;
GOW ;
HUNYOR ;
BROD ;
OROURKE .
AUSTRALIAN AND NEW ZEALAND JOURNAL OF MEDICINE, 1976, 6 :49-59