Comparison of ultrasound pachymetry and partial coherence interferometry in the measurement of central corneal thickness

被引:71
作者
Rainer, G
Petternel, V
Findl, O
Schmetterer, L
Skorpik, C
Luksch, A
Drexler, W
机构
[1] Univ Vienna, Dept Ophthalmol, A-1090 Vienna, Austria
[2] Univ Vienna, Inst Med Phys, A-1090 Vienna, Austria
[3] Univ Vienna, Dept Clin Pharmacol, A-1090 Vienna, Austria
关键词
D O I
10.1016/S0886-3350(02)01533-X
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To compare central corneal thickness (CCT) measurements obtained with 3 ultrasound pachymeters and with partial coherence interferometry (PCI) and evaluate the effect of repeated contact by a pachymetry probe on corneal thickness. Setting: Department of Ophthalmology, University of Vienna, Vienna, Austria. Methods: Central corneal thickness was measured in 20 eyes of 20 healthy volunteers with 3 different ultrasound pachymeters (DGH 500, DGH Technology Inc.; SP 2000, Tomey Inc.; Paxis, Biovision Inc.) and with PCI. In each eye, 5 measurements with PCI were followed by 5 measurements with each ultrasound pachymetry device and another 5 measurements with PCI. Results: The mean CCT measured with the DGH 500, SP 2000, and Paxis was 541.0 mum, 539.2 mum, and 545.1 mum, respectively. Although the differences among the 3 ultrasound pachymetry devices were within 6.0 mum, they were statistically significant (P < .05). The PCI measurements were significantly smaller (P < .05) than the ultrasound measurements: 518.8 mum before and 517.5 mum after repeated contact with the ultrasound pachymetry probe (P < .05). The mean precision (standard deviation) was 0.77 mum for PCI and between 2.40 mum and 3.58 mum for ultrasound pachymetry measurements. The correlation coefficients for the intraobserver variability were 0.999 for PCI and between 0.987 and 0.995 for ultrasound pachymetry measurements. Conclusions: Partial coherence interferometry was the more precise method of measuring CCT and had better intraobserver variability. Repeated contact by a pachymetry probe reduced corneal thickness by 1.3 mum. However, the reason for the smaller measurements with PCI than with ultrasound pachymetry remains unclear. (C) 2002 ASCRS and ESCRS.
引用
收藏
页码:2142 / 2145
页数:4
相关论文
共 18 条
[1]   Corneal ectasia after laser in situ keratomileusis [J].
Argento, C ;
Cosentino, MJ ;
Tytiun, A ;
Rapetti, G ;
Zarate, J .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2001, 27 (09) :1440-1448
[2]   Central corneal thickness measurement with a retinal optical coherence tomography device versus standard ultrasonic pachymetry [J].
Bechmann, M ;
Thiel, MJ ;
Neubauer, AS ;
Ullrich, S ;
Ludwig, K ;
Kenyon, KR ;
Ulbig, MW .
CORNEA, 2001, 20 (01) :50-54
[3]  
Bovelle R, 1999, ARCH OPHTHALMOL-CHIC, V117, P868
[4]   Investigation of dispersion effects in ocular media by multiple wavelength partial coherence interferometry [J].
Drexler, W ;
Hitzenberger, CK ;
Baumgartner, A ;
Findl, O ;
Sattmann, H ;
Fercher, AF .
EXPERIMENTAL EYE RESEARCH, 1998, 66 (01) :25-33
[5]  
Drexler W, 1997, INVEST OPHTH VIS SCI, V38, P1304
[6]   MEASUREMENT OF THE THICKNESS OF FUNDUS LAYERS BY PARTIAL COHERENCE TOMOGRAPHY [J].
DREXLER, W ;
HITZENBERGER, CK ;
SATTMANN, H ;
FERCHER, AF .
OPTICAL ENGINEERING, 1995, 34 (03) :701-710
[7]   VARIABILITY OF ULTRASONIC PACHOMETRY [J].
GORDON, A ;
BOGGESS, EA ;
MOLINARI, JF .
OPTOMETRY AND VISION SCIENCE, 1990, 67 (03) :162-165
[8]   Corneal ectasia detected after laser in situ keratomileusis for correction of less than-12 diopters of myopia [J].
Joo, CK ;
Kim, TG .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2000, 26 (02) :292-295
[9]   CLINICAL BIOSTATISTICS .54. THE BIOSTATISTICS OF CONCORDANCE [J].
KRAMER, MS ;
FEINSTEIN, AR .
CLINICAL PHARMACOLOGY & THERAPEUTICS, 1981, 29 (01) :111-123
[10]   The repeatability of corneal thickness measures [J].
Marsich, MM ;
Bullimore, MA .
CORNEA, 2000, 19 (06) :792-795