Strain rate imaging: An in vitro "validation" study using a physiologic balloon model mimicking the left ventricle

被引:7
作者
Hashimoto, I [1 ]
Mori, Y [1 ]
Rusk, RA [1 ]
Davies, CH [1 ]
Li, XK [1 ]
Mack, GK [1 ]
Sahn, DJ [1 ]
机构
[1] Oregon Hlth & Sci Univ, Portland, OR 97201 USA
来源
ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES | 2002年 / 19卷 / 08期
关键词
tissue Doppler imaging; strain rate imaging; echocardiography; left ventricular function;
D O I
10.1046/j.1540-8175.2002.00669.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Strain rate imaging (SRI) can be implemented from digital ultrasound loops of tissue Doppler imaging (TDI) data and is performed as an autocorrelation solution of the distance between intramyocardial targets. As such, it should have better resolution along longer distances of wall segments that are imaged at the length of individual ultrasound scan lines. Methods: We used a new left ventricular double-balloon phantom with a tissue-mimicking gel between the walls. Mounted in a water bath and connected to a pulsatile flow pump at four-stroke volume (30-50 ml/beat), the high frame rate, digital, multiple two-dimensional/tissue/TDI loops of balloon wall motion were recorded using a GE VingMed system FiVe (3.5 MHz phased array transducer), with the model scanned longitudinally from the apex. The strain rate (SR) values were measured at the apex and the lateral wall using an offline measurement program, and mean SR values for every 100 msec were calculated by averaging three determinations at each point. The excursions of the apex and lateral wall also were measured directly by high speed digital video imaging, and consecutive velocity profiles were calculated every 100 msec. A total of 40 data points for four-stroke volumes were analyzed. Results: While our balloon model had enough gel targets between the walls to produce a good mimic of myocardial speckle with walls that thickened and thinned, samples immediately across the apex and apex SR values (Hz) varied substantially. In contrast, systematic signals could be obtained from lines imaged >15degrees from the true apex and crossing a longer length of myocardium. At the lateral wall, there was a close correlation between the video velocities and SR values, as well as a close overlap of the phasic patterns. Conclusions: SRI produces more reliable data from wall segments parallel to scan lines.
引用
收藏
页码:669 / 677
页数:9
相关论文
共 26 条
[1]   NONINVASIVE QUANTIFICATION OF PRINCIPAL STRAINS IN NORMAL CANINE HEARTS USING TAGGED MRI IMAGES IN 3-D [J].
AZHARI, H ;
WEISS, JL ;
ROGERS, WJ ;
SIU, CO ;
ZERHOUNI, EA ;
SHAPIRO, EP .
AMERICAN JOURNAL OF PHYSIOLOGY, 1993, 264 (01) :H205-H216
[2]   INTRAMURAL MECHANICS IN HYPERTROPHIC CARDIOMYOPATHY - FUNCTIONAL MAPPING WITH STRAIN-RATE MR-IMAGING [J].
BEACHE, GM ;
WEDEEN, VJ ;
WEISSKOFF, RM ;
OGARA, PT ;
PONCELET, BP ;
CHESLER, DA ;
BRADY, TJ ;
ROSEN, BR ;
DINSMORE, RE .
RADIOLOGY, 1995, 197 (01) :117-124
[3]   MYOCARDIAL VELOCITY-GRADIENTS DETECTED BY DOPPLER IMAGING [J].
FLEMING, AD ;
XIA, X ;
MCDICKEN, WN ;
SUTHERLAND, GR ;
FENN, L .
BRITISH JOURNAL OF RADIOLOGY, 1994, 67 (799) :679-688
[4]   Contraction and relaxation velocities of the normal left ventricle using pulsed-wave tissue Doppler echocardiography [J].
Galiuto, L ;
Ignone, G ;
DeMaria, AN .
AMERICAN JOURNAL OF CARDIOLOGY, 1998, 81 (05) :609-614
[5]   Color-coded measures of myocardial velocity throughout the cardiac cycle by tissue Doppler imaging to quantify regional left ventricular function [J].
Gorcsan, J ;
Gulati, VK ;
Mandarino, WA ;
Katz, WE .
AMERICAN HEART JOURNAL, 1996, 131 (06) :1203-1213
[6]   Quantitative assessment of alterations in regional left ventricular contractility with color-coded tissue Doppler echocardiography - Comparison with sonomicrometry and pressure-volume relations [J].
Gorcsan, J ;
Strum, DP ;
Mandarino, WA ;
Gulati, VK ;
Pinsky, MR .
CIRCULATION, 1997, 95 (10) :2423-2433
[7]  
Gotteiner N L, 1995, Am J Card Imaging, V9, P185
[8]   Mitral annular descent velocity by tissue Doppler echocardiography as an index global left ventricular function [J].
Gulati, VK ;
Katz, WE ;
Follansbee, WP ;
Gorcsan, J .
AMERICAN JOURNAL OF CARDIOLOGY, 1996, 77 (11) :979-984
[9]   Real-time strain rate imaging of the left ventricle by ultrasound [J].
Heimdal, A ;
Stoylen, A ;
Torp, H ;
Skjaerpe, T .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 1998, 11 (11) :1013-1019
[10]   Abnormal postsystolic thickening in acutely ischemic myocardium during coronary angioplasty: A velocity, strain, and strain rate Doppler myocardial imaging study [J].
Jamal, F ;
Kukulski, T ;
D'hooge, T ;
De Scheerder, I ;
Sutherland, G .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 1999, 12 (11) :994-996