Stack Degradation in Dependence of Operation Parameters; the Real-SOFC Sensitivity Analysis

被引:78
作者
de Haart, L. G. J. [1 ]
Mougin, J. [2 ]
Posdziech, O. [3 ]
Kiviaho, J. [4 ]
Menzler, N. H. [5 ]
机构
[1] Forschungszentrum Julich GmbH, Inst Energy Res Fuel Cells IEF 3, D-52425 Julich, Germany
[2] CEA Grenoble, DRT LITEN DTH LEV, F-38054 Grenoble 9, France
[3] EBZ Entwicklungs & Vertriebsgesell Brennstoffzell, D-01307 Dresden, Germany
[4] VTT Tech Res Ctr Finland, FI-02044 Espoo, Finland
[5] Forschungszentrum Julich GmbH, Inst Energy Res Mat Synth & Proc IEF 1, D-52425 Julich, Germany
关键词
Degradation; Durability; SOFC; Solid Oxide Fuel Cell; Testing; PERFORMANCE;
D O I
10.1002/fuce.200800146
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
The EU Integrated Project Real-SOFC aims at improving the understanding of degradation in SOFC stacks, and extending the durability of planar SOFC stacks to degradation rates suitable for stationary application. As part of the Real-SOFC project, three series of SOFC stacks, each with two or four planar anode-supported cells, were operated for durations of 3,000 h up to 10,000 h under varying fuel and electrical load conditions. The durability tests on these short stacks were conducted galvanostatically at 800 and 700 degrees C in dependence of current-density (0.3, 0.5 or 0.7 A cm(-2)), of fuel composition (hydrogen: H-2 + 3-10% H2O or methane: CH4/H2O (SIC = 2)) and of fuel utilisation (8, 40, 60 or 75%). A pronounced difference in degradation behaviour was observed between the stacks operated at different current densities. The degradation behaviour was, however, not influenced by the choice of fuel (hydrogen or methane) and was hardly influenced by the fuel utilisation. Lowest degradation rates of about 20 m Omega cm(2) kh(-1) were determined for the tests of a short stack with cells with LSM cathodes operated at 800 degrees C and a current-density of 0.3 A cm(-2) and of a short stack with cells with LSCF cathodes operated at 700 degrees C and a current-density of 0.5 A cm(-2). Post-test characterisation of the cathode with respect to chromium poisoning was performed on cells from several stacks. No clear relationship between the degradation rate of the stacks and amount of Cr incorporated in the cathode could be established. The major difference was a change in microstructure of the cathode in the region near the electrolyte interface; in the stacks operated at lower current densities, the structurally changed zone was clearly thinner than in those stacks operated at higher currents.
引用
收藏
页码:794 / 804
页数:11
相关论文
共 10 条
[1]  
BLUM L, 2005, ELECTROCHEMICAL SOC, P39
[2]   Optimisation of processing and microstructural parameters of LSM cathodes to improve the electrochemical performance of anode-supported SOFCs [J].
Haanappel, VAC ;
Mertens, J ;
Rutenbeck, D ;
Tropartz, C ;
Herzhof, W ;
Sebold, D ;
Tietz, F .
JOURNAL OF POWER SOURCES, 2005, 141 (02) :216-226
[3]   Chromium vapor species over solid oxide fuel cell interconnect materials and their potential for degradation processes [J].
Hilpert, K ;
Das, D ;
Miller, M ;
Peck, DH ;
Weiss, R .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1996, 143 (11) :3642-3647
[4]   Dynamics of fuel cell performance degradation [J].
Kulikovsky, AA ;
Scharmann, H ;
Wippermann, K .
ELECTROCHEMISTRY COMMUNICATIONS, 2004, 6 (01) :75-82
[5]   Studies of material interaction after long-term stack operationx [J].
Menzler, N. H. ;
Batfalsky, P. ;
Blum, L. ;
Bram, M. ;
Gross, S. M. ;
Haanappel, V. A. C. ;
Malzbender, J. ;
Shemet, V. ;
Steinbrech, R. W. ;
Vinke, I. .
FUEL CELLS, 2007, 7 (05) :356-363
[6]  
Menzler NH, 2002, MATERIALWISS WERKST, V33, P367, DOI 10.1002/1521-4052(200206)33:6<367::AID-MAWE367>3.0.CO
[7]  
2-4
[8]   Characterization of Cathode Chromium Incorporation during Mid-Term Stack Operation under Various Operational Conditions [J].
Menzler, Norbert H. ;
de Haart, L. G. J. ;
Sebold, Doris .
SOLID OXIDE FUEL CELLS 10 (SOFC-X), PTS 1 AND 2, 2007, 7 (01) :245-254
[9]   Real-SOFC - A Joint European Effort In Understanding SOFC Degradation [J].
Steinberger-Wilckens, Robert ;
Tietz, Frank ;
Smith, Martin J. ;
Mougin, Julie ;
Rietveld, Bert ;
Bucheli, Olivier ;
van Herle, Jan ;
Rosenberg, Rolf ;
Zahid, Mohsine ;
Holtappels, Peter .
SOLID OXIDE FUEL CELLS 10 (SOFC-X), PTS 1 AND 2, 2007, 7 (01) :67-+
[10]  
STEINBERGERWILC.R, 2006, P 7 EUR SOFC FOR LUC