A MitoTracker Green-based flow cytometric assay for natural killer cell activity: Variability, the influence of platelets and a comparison of analytical approaches

被引:12
作者
Hopkinson, Kay
Williams, Elizabeth A.
Fairburn, Barbara
Forster, Sarah
Flower, Daniel J.
Saxton, John M.
Pockley, A. Graham
机构
[1] Univ Sheffield, Immunobiol Res Unit, Royal Hallamshire Hosp, Sheffield S10 2JF, S Yorkshire, England
[2] Univ Sheffield, Human Nutr Unit, Sch Med & Biomed Sci, Sheffield S10 2JF, S Yorkshire, England
[3] Sheffield Hallam Univ, Ctr Sport & Exercise Sci, Sheffield S1 1WB, S Yorkshire, England
关键词
D O I
10.1016/j.exphem.2006.12.001
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective. A number of flow cytometric assays for natural killer (NK) cell cytotoxicity have been described, however, the relative merits of analytical approaches and the influence of platelets on measured responses have not been systematically evaluated. Information on the time-dependent variability in measured responses is also limited. Matetials and Methods. Human peripheral blood mononuclear cells were obtained using Nycoprep 1.077, or Nycoprep 1.077 followed by Nycoprep 1.068 (to remove platelets), and incubated for 3 hours with MitoTracker Green (MTG)-labeled K562 cells. Cells were stained with propidium iodide (PI) and the proportions of viable and nonviable target cells (MTG(+)PI(-), MTG(+)PI(+)) were determined by flow cytometry using quadrant and polygonal region analysis. Results. Platelets inhibited NK cell cytotoxicity and the response was underestimated when the nonviable target cell population was not entirely enclosed within the nonviable target cell (upper right) flow cytometric quadrant. The variability in measured NK cell cytotoxic responses in samples obtained from five individuals on three occasions over a 3-week period was 28%, 24%, 26%, and 37%, and 19%, 23%,27%, and 32% for the quadrant and region analyses (mean coefficient of variation at effector-to-target cell ratios of 100:1, 50:1, 25:1, and 12.5:1, respectively), and 24% and 20% when data were calculated as the area under the cytotoxic curve (AUCC). Conclusion. Polygonal regions and the calculation of data as the AUCC appear to be the best approach. This study will be of value to investigators that are wishing to incorporate an NK cell cytotoxicity assay into their portfolio of experimental techniques. (c) 2007 International Society for Experimental Hematology. Published by Elsevier Inc.
引用
收藏
页码:350 / 357
页数:8
相关论文
共 22 条
[1]  
CHANG L, 1993, J IMMUNOL METHODS, V166, P45
[2]   EFFECTOR-TARGET INTERACTIONS - SATURABILITY, AFFINITY AND BINDING ISOTHERMS - A STUDY OF SUCH INTERACTIONS IN THE HUMAN NK CELL-K562 TUMOR-CELL SYSTEM [J].
GARCIAPENARRUBIA, P ;
CABRERA, L ;
ALVAREZ, R ;
GALVEZ, J .
JOURNAL OF IMMUNOLOGICAL METHODS, 1992, 155 (01) :133-147
[3]   A novel method for the simultaneous assessment of natural killer cell conjugate formation and cytotoxicity at the single-cell level by multi-parameter flow cytometry [J].
Godoy-Ramirez, K ;
Franck, K ;
Gaines, H .
JOURNAL OF IMMUNOLOGICAL METHODS, 2000, 239 (1-2) :35-44
[4]   A flow-cytometry based cytotoxicity assay using stained effector cells in combination with native target cells [J].
Höppner, M ;
Luhm, J ;
Schlenke, P ;
Koritke, P ;
Frohn, C .
JOURNAL OF IMMUNOLOGICAL METHODS, 2002, 267 (02) :157-163
[5]   Determination of natural killer cell function by flow cytometry [J].
Kane, KL ;
Ashton, FA ;
Schmitz, JL ;
Folds, JD .
CLINICAL AND DIAGNOSTIC LABORATORY IMMUNOLOGY, 1996, 3 (03) :295-300
[6]   A novel enhanced green fluorescent protein (EGFP)-K562 flow cytometric method for measuring natural killer (NK) cell cytotoxic activity [J].
Kantakamalakul, W ;
Jaroenpool, H ;
Pattanapanyasat, K .
JOURNAL OF IMMUNOLOGICAL METHODS, 2003, 272 (1-2) :189-197
[7]   Comparative study of NK cell-mediated cytotoxicity using radioactive and flow cytometric cytotoxicity assays [J].
Langhans, B ;
Ahrendt, M ;
Nattermann, J ;
Sauerbruch, T ;
Spengler, U .
JOURNAL OF IMMUNOLOGICAL METHODS, 2005, 306 (1-2) :161-168
[8]   Development of a novel flow cytometric cell-mediated cytotoxicity assay using the fluorophores PKH-26 and TO-PRO-3 iodide [J].
Lee-MacAry, AE ;
Ross, EL ;
Davies, D ;
Laylor, R ;
Honeychurch, J ;
Glennie, MJ ;
Snary, D ;
Wilkinson, RW .
JOURNAL OF IMMUNOLOGICAL METHODS, 2001, 252 (1-2) :83-92
[9]   ANALYSIS OF CELL-POPULATIONS WITH A FLUORESCENCE-ACTIVATED CELL SORTER [J].
LOKEN, MR ;
HERZENBERG, LA .
ANNALS OF THE NEW YORK ACADEMY OF SCIENCES, 1975, 254 :163-171
[10]  
MADSEN PS, 1986, ACTA PATH MICRO IM C, V94, P193