Measurement of chloramphenicol by capillary zone electrophoresis following end-column amperometric detection at a carbon fiber micro-disk array electrode

被引:42
作者
Jin, WR [1 ]
Ye, XY [1 ]
Yu, DQ [1 ]
Dong, Q [1 ]
机构
[1] Shandong Univ, Sch Chem, Sci Analyt Lab, Jinan 250100, Peoples R China
来源
JOURNAL OF CHROMATOGRAPHY B | 2000年 / 741卷 / 02期
基金
中国国家自然科学基金;
关键词
chloramphenicol; capillary electrophoresis; electrochemical detection;
D O I
10.1016/S0378-4347(00)00049-9
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Capillary zone electrophoresis was employed for the measurement of chloramphenicol using end-column amperometric detection with a carbon fiber micro-disk array electrode, at a constant potential of -1.00 V vs, saturated calomel electrode. The effect of oxygen in the buffer has been investigated. It is found that when the area of the carbon fiber electrode is smaller than 1.1 mm(2), the interference of oxygen can be overcome. In this procedure deoxygenation is not necessary. The effect of pH, the concentration of the buffer and the high separation voltage across the capillary on the migration time, electrophoretic peak current and separation efficiency has been studied. The optimum conditions of separation and detection are 8.4 x 10(-4) mol/l HOAc-3.2 x 10(-3) mol/l NaOAc for the buffer solution, 20 kV for the separation voltage, 5 kV and 5 s for the injection voltage and the injection time, respectively. The calibration plot was found to be linear in the range 5 x 10(-6) to 1 x 10(-3) mol/l and the limit of detection is 9.1 x 10(-7) mol/l or 1.4 fmol (S/N = 2). The relative standard deviation is 1.1% for the migration time and 2.3% for the electrophoretic peak current. The method was applied to the determination of chloramphenicol in human serum. (C) 2000 Published by Elsevier Science B.V. All rights reserved.
引用
收藏
页码:155 / 162
页数:8
相关论文
共 20 条
[1]   ASSAY OF CHLORAMPHENICOL IN BIOLOGICAL MEDIA BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH UV ABSORBENCY AS THE DETECTION MODE [J].
DUBOURG, D ;
SAUX, MC ;
LEFEBVRE, MA ;
FOURTILLAN, JB .
JOURNAL OF LIQUID CHROMATOGRAPHY, 1987, 10 (05) :921-940
[2]  
ELYAZIGI A, 1987, CLIN CHEM, V33, P1814
[3]   Adsorption-voltammetric determination of guanine, guanosine, adenine and adenosine with capillary zone electrophoresis separation [J].
Jin, WR ;
Wei, HY ;
Zhao, X .
ANALYTICA CHIMICA ACTA, 1997, 347 (03) :269-274
[4]   Determination of bovine serum albumin by capillary zone electrophoresis with end-column amperometric detection at the carbon fiber microdisk array electrode [J].
Jin, WR ;
Weng, QF ;
Wu, JR .
ANALYTICA CHIMICA ACTA, 1997, 342 (01) :67-74
[5]   Voltammetric characteristics of adenine and adenosine at a copper electrode and their application to end-column amperometric detection for capillary zone electrophoresis [J].
Jin, WR ;
Wei, HY ;
Li, W ;
Zhao, X .
ANALYTICAL LETTERS, 1997, 30 (04) :771-785
[6]   Determination of adenine and guanine by capillary zone electrophoresis with end-column amperometric detection at a carbon fiber microdisk array electrode [J].
Jin, WR ;
Wei, HY ;
Zhao, X .
ELECTROANALYSIS, 1997, 9 (10) :770-774
[7]   Theory concerning the current for an end-column amperometric detector with a disk working electrode in capillary zone electrophoresis [J].
Jin, WR ;
Chen, HF .
JOURNAL OF CHROMATOGRAPHY A, 1997, 765 (02) :307-314
[8]  
Jin WR, 1997, J ELECTROANAL CHEM, V425, P155
[9]   Capillary zone electrophoresis with end-column amperometric detection for the determination of glutathione at a gold/mercury amalgam microelectrode without deoxygenation [J].
Jin, WR ;
Wang, Y .
ANALYTICA CHIMICA ACTA, 1997, 343 (03) :231-239
[10]   HIGH-RESOLUTION SEPARATIONS BASED ON ELECTROPHORESIS AND ELECTROOSMOSIS [J].
JORGENSON, JW ;
LUKACS, KD .
JOURNAL OF CHROMATOGRAPHY, 1981, 218 (1-3) :209-216