Measurement of induced magnetic flux density using injection current nonlinear encoding (ICNE) in MREIT

被引:51
作者
Park, Chunjae [1 ]
Lee, Byung Il
Kwon, Ohin
Woo, Eung Je
机构
[1] Kyung Hee Univ, Coll Electron & Informat, Seoul, South Korea
[2] Konkuk Univ, Dept Math, Seoul, South Korea
关键词
MREIT; conductivity image; magnetic flux density; injection current nonlinear encoding;
D O I
10.1088/0967-3334/28/2/001
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Magnetic resonance electrical impedance tomography (MREIT) measures induced magnetic flux densities subject to externally injected currents in order to visualize conductivity distributions inside an electrically conducting object. Injection currents induce magnetic flux densities that appear in phase parts of acquired MR image data. In the conventional current injection method, we inject currents during the time segment between the end of the first RF pulse and the beginning of the reading gradient in order to ensure the gradient linearity. Noting that longer current injections can accumulate more phase changes, we propose a new pulse sequence called injection current nonlinear encoding (ICNE) where the duration of the injection current pulse is extended until the end of the reading gradient. Since the current injection during the reading gradient disturbs the gradient linearity, we first analyze the MR signal produced by the ICNE pulse sequence and suggest a novel algorithm to extract the induced magnetic flux density from the acquired MR signal. Numerical simulations and phantom experiments show that the new method is clearly advantageous in terms of the reduced noise level in measured magnetic flux density data. The amount of noise reduction depends on the choice of the data acquisition time and it was about 24% when we used a prolonged data acquisition time of 10.8ms. The ICNE method will enhance the clinical applicability of the MREIT technique when it is combined with an appropriate phase artefact minimization method.
引用
收藏
页码:117 / 127
页数:11
相关论文
共 23 条
[1]  
Eyuboglu M., 2001, P 11 INT C EL BIOIMP, P409
[2]  
Haacke EM, 1999, MAGNETIC RESONANCE I
[3]  
Ider YZ., 1998, ELEKTRIK, V6, P215
[4]   INVIVO DETECTION OF APPLIED ELECTRIC CURRENTS BY MAGNETIC-RESONANCE IMAGING [J].
JOY, M ;
SCOTT, G ;
HENKELMAN, M .
MAGNETIC RESONANCE IMAGING, 1989, 7 (01) :89-94
[5]  
Joy MLG, 2004, P ANN INT IEEE EMBS, V26, P5315
[6]   J-substitution algorithm in Magnetic Resonance Electrical Impedance Tomography (MREIT):: Phantom experiments for static resistivity images [J].
Khang, HS ;
Lee, BI ;
Oh, SH ;
Woo, EJ ;
Lee, SY ;
Cho, MY ;
Kwon, O ;
Yoon, JR ;
Seo, JK .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2002, 21 (06) :695-702
[7]   Magnetic resonance electrical impedance tomography (MREIT):: Simulation study of J-substitution algorithm [J].
Kwon, O ;
Woo, EJ ;
Yoon, JR ;
Seo, JK .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2002, 49 (02) :160-167
[8]   Three-dimensional forward solver and its performance analysis for magnetic resonance electrical impedance tomography (MREIT) using recessed electrodes [J].
Lee, BI ;
Oh, SH ;
Woo, EJ ;
Lee, SY ;
Cho, MH ;
Kwon, O ;
Seo, JK ;
Lee, JY ;
Baek, WS .
PHYSICS IN MEDICINE AND BIOLOGY, 2003, 48 (13) :1971-1986
[9]   Phase artefact reduction in magnetic resonance electrical impedance tomography (MREIT) [J].
Lee, Byung Il ;
Park, Chunjae ;
Pyo, Hyun Chan ;
Kwon, Ohin ;
Woo, Eung Je .
PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (20) :5277-5288
[10]   Resolution and contrast in magnetic resonance electrical impedance tomography (MREIT) and its application to cancer imaging [J].
Muftuler, LT ;
Hamamura, M ;
Birgul, O ;
Nalcioglu, O .
TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2004, 3 (06) :599-609