Evaluation of the titanium dioxide approach for MS analysis of phosphopeptides

被引:52
作者
Klemm, Clementine [1 ]
Otto, Sebastian [1 ]
Wolf, Constanze [1 ]
Haseloff, Reiner F. [1 ]
Beyermann, Michael [1 ]
Krause, Eberhard [1 ]
机构
[1] Leibniz Inst Mol Pharmakol, D-13125 Berlin, Germany
来源
JOURNAL OF MASS SPECTROMETRY | 2006年 / 41卷 / 12期
关键词
phosphopeptides; titanium dioxide microcolumn; electrospray ionization; matrix-assisted laser desorption /ionization; tandem mass spectrometry;
D O I
10.1002/jms.1129
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The affinity of titanium dioxide for phosphate groups has been successfully used for enrichment of phosphopeptides from complex mixtures. This paper reports the relationship between the occurrence of some amino acids and the phospho-specific and nonspecific binding of peptides that occurs during titanium dioxide enrichment. In order to perform a systematic study, two well-characterized peptide mixtures consisting of either 33 or 8 synthetic phosphopeptides and their nonphosphorylated analogs, which differed in charge and hydrophobicity, were synthesized and analyzed by ESI-MS and MALDI-MS. The titanium dioxide procedure was also evaluated for comprehensive detection of phosphopeptides in phosphoproteomics. In summary, our results clearly confirm the high selectivity of titanium dioxide for phosphorylated sequences. Drastically reduced recovery was observed for phosphopeptides with multiple basic amino acids. Nonspecific binding of nonphosphorylated peptides and sample loss of phosphopeptides must also be taken into account. Copyright (c) 2006 John Wiley & Sons, Ltd.
引用
收藏
页码:1623 / 1632
页数:10
相关论文
共 37 条
[1]   Selective analysis of phosphopeptides within a protein mixture by chemical modification, reversible biotinylation and mass spectrometry [J].
Adamczyk, M ;
Gebler, JC ;
Wu, J .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2001, 15 (16) :1481-1488
[2]   Femtomol sensitivity post-digest 18O labeling for relative quantification of differential protein complex composition [J].
Bantscheff, M ;
Dümpelfeld, B ;
Kuster, B .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2004, 18 (08) :869-876
[3]   The contributions of specific amino acid side chains to signal intensities of peptides in matrix-assisted laser desorption/ionization mass spectrometry [J].
Baumgart, S ;
Lindner, Y ;
Kühne, R ;
Oberemm, A ;
Wenschuh, H ;
Krause, E .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2004, 18 (08) :863-868
[4]   Phosphate adsorption onto TiO2 from aqueous solutions:: An in situ internal reflection infrared spectroscopic study [J].
Connor, PA ;
McQuillan, AJ .
LANGMUIR, 1999, 15 (08) :2916-2921
[5]   Cloning of a novel T-cell protein FYB that binds FYN and SH2-domain-containing leukocyte protein 76 and modulates interleukin 2 production [J].
DaSilva, AJ ;
Li, ZW ;
DeVera, C ;
Canto, E ;
Findell, P ;
Rudd, CE .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1997, 94 (14) :7493-7498
[6]   Phosphoproteome analysis by mass spectrometry and its application to Saccharomyces cerevisiae [J].
Ficarro, SB ;
McCleland, ML ;
Stukenberg, PT ;
Burke, DJ ;
Ross, MM ;
Shabanowitz, J ;
Hunt, DF ;
White, FM .
NATURE BIOTECHNOLOGY, 2002, 20 (03) :301-305
[7]   Phosphoprotein isotope-coded affinity tag approach for isolating and quantitating phosphopeptides in proteome-wide analyses [J].
Goshe, MB ;
Conrads, TP ;
Panisko, EA ;
Angell, NH ;
Veenstra, TD ;
Smith, RD .
ANALYTICAL CHEMISTRY, 2001, 73 (11) :2578-2586
[8]   Communication between the TCR and integrins: role of the molecular adapter ADAP/Fyb/Slap [J].
Griffiths, EK ;
Penninger, JM .
CURRENT OPINION IN IMMUNOLOGY, 2002, 14 (03) :317-322
[9]   Differential protein expression in brain capillary endothelial cells induced by hypoxia and posthypoxic reoxygenation [J].
Haseloff, RF ;
Krause, E ;
Bigl, M ;
Mikoteit, K ;
Stanimirovic, D ;
Blasig, IE .
PROTEOMICS, 2006, 6 (06) :1803-1809
[10]   Phosphopeptide analysis by positive and negative ion matrix-assisted laser desorption/ionization mass spectrometry [J].
Janek, K ;
Wenschuh, H ;
Bienert, M ;
Krause, E .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2001, 15 (17) :1593-1599