High frame-rate simultaneous bilateral breast DCE-MRI

被引:30
作者
Dougherty, Lawrence
Isaac, Gamaliel
Rosen, Mark A.
Nunes, Linda W.
Moate, Peter J.
Boston, Raymond C.
Schnall, Mitchell D.
Song, Hee Kwon
机构
[1] Hosp Univ Penn, Dept Radiol, Philadelphia, PA 19104 USA
[2] Penn Hosp, Dept Radiol, Philadelphia, PA 19107 USA
[3] Univ Penn, Sch Vet Med, Philadelphia, PA 19104 USA
关键词
MRI; breast; contrast; radial; cancer;
D O I
10.1002/mrm.21114
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A simultaneous bilateral back-projection method for 3D dynamic contrast-enhanced (DCE)-MRI of the breasts was developed and evaluated. Using a double-side band modulation of the RF slab excitation pulse, discontinuous volumes that included both breasts were simultaneously selected. The number of slice phase-encoding steps was undersampled by a factor of 2, and the resulting signal aliasing from one volume to the other was removed using SENSE processing. In-plane encoding was performed with an interleaved radial acquisition reconstructed using dynamic k-space-weighted image contrast (KWIC) temporal filtering. Image resolution was 0.5 x 0.5 x 3.0 mm(3) with an effective temporal resolution of 15 s for both breast volumes. Combined with the 2x acceleration from SENSE encoding, this is a 16x acceleration factor over a conventional MR bilateral breast scan. An initial evaluation of these methods was performed on a cohort of women who presented with palpable or mammographically visible breast abnormalities. A total of 73 abnormalities were found in 45 of the 54 bilateral examinations that were performed. In 11 of these cases there was a significant finding in the contralateral breast. DCE images of both breasts can be acquired simultaneously, resulting in high-resolution images as well as rapid sampling of the contrast kinetics.
引用
收藏
页码:220 / 225
页数:6
相关论文
共 30 条
[1]   SENSE imaging of the breast [J].
Friedman, PD ;
Swaminathan, SV ;
Smith, R .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2005, 184 (02) :448-451
[2]   MR IMAGING OF THE BREAST USING GADOLINIUM-DTPA [J].
HEYWANG, SH ;
HAHN, D ;
SCHMIDT, H ;
KRISCHKE, I ;
EIERMANN, W ;
BASSERMANN, R ;
LISSNER, J .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1986, 10 (02) :199-204
[3]   MR IMAGING OF THE BREAST WITH GD-DTPA - USE AND LIMITATIONS [J].
HEYWANG, SH ;
WOLF, A ;
PRUSS, E ;
HILBERTZ, T ;
EIERMANN, W ;
PERMANETTER, W .
RADIOLOGY, 1989, 171 (01) :95-103
[4]   EXPERIMENTAL SIMULATION EVALUATION OF ECG-GATED HEART SCANS WITH A SMALL NUMBER OF VIEWS [J].
JOSEPH, PM ;
WHITLEY, J .
MEDICAL PHYSICS, 1983, 10 (04) :444-449
[5]   MR IMAGING OF THE BREAST - FAST IMAGING SEQUENCES WITH AND WITHOUT GD-DTPA - PRELIMINARY-OBSERVATIONS [J].
KAISER, WA ;
ZEITLER, E .
RADIOLOGY, 1989, 170 (03) :681-686
[6]   Dynamic breast MR imaging: Are signal intensity time course data useful for differential diagnosis of enhancing lesions? [J].
Kuhl, CK ;
Mielcareck, P ;
Klaschik, S ;
Leutner, C ;
Wardelmann, E ;
Gieseke, J ;
Schild, HH .
RADIOLOGY, 1999, 211 (01) :101-110
[7]   An investigation into the use of sensitivity-encoded techniques to increase temporal resolution in dynamic contrast-enhanced breast imaging [J].
Larkman, DJ ;
deSouza, NM ;
Bydder, M ;
Hajnal, JV .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2001, 14 (03) :329-335
[8]  
Larkman DJ, 2001, J MAGN RESON IMAGING, V13, P313, DOI 10.1002/1522-2586(200102)13:2<313::AID-JMRI1045>3.3.CO
[9]  
2-N
[10]   MR Imaging screening of the contralateral breast in patients with newly diagnosed breast cancer: Preliminary results [J].
Lee, SG ;
Orel, SG ;
Woo, IJ ;
Cruz-Jove, E ;
Putt, ME ;
Solin, LJ ;
Czerniecki, BJ ;
Schnall, MD .
RADIOLOGY, 2003, 226 (03) :773-778