Ultimate sensitivity of time-resolved opto-acoustic detection

被引:74
作者
Oraevsky, A [1 ]
Karabutov, A [1 ]
机构
[1] Univ Texas, Med Branch, CBME, Optoacoust Imaging & Spect Lab, Galveston, TX 77555 USA
来源
BIOMEDICAL OPTOACOUSTICS | 2000年 / 3916卷
关键词
piezoelectric transducer; optical vibrometer; opto-acoustic imaging;
D O I
10.1117/12.386326
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
The major limitation in sensitivity of the optical tomography is associated with strong optical attenuation in human tissues. Opto-Acoustic Tomography overcomes this limitation utilizing detection of acoustic waves instead of detection of transmitted photons. Exceptional sensitivity of the opto-acoustic tomography allows early detection of small tumors located deep in human tissues, such as breast. This paper demonstrates that an optimally designed opto-acoustic imaging system can detect early l-mm tumors with minimal blood content of only 7% at the depth of up to 7-cm within the breast attenuating laser irradiation 3.3 times per each 1-cm of its depth. A theoretical consideration of the ultimate sensitivity of piezo-detection in a wide ultrasonic frequency band is developed. The detection sensitivity is presented as a function of the ultrasonic frequency, tumor dimensions and optical absorption coefficient. Comparative analysis of piezo and optical interferometric detection of opto-acoustic transients is presented. The theoretical models of piezo-detection were developed for the open-circuit and short-circuit schemes of operation. The ultimate sensitivity limited by thermal noise of electric capacitor of the piezo-element was estimated. It was shown that the limit of detection depends on the frequency band, the electric capacity of the transducer and the speed of sound in the piezo-element. Comparative analysis of various piezo-materials was made from the point of view of their utility for sensitive opto-acoustic detection.
引用
收藏
页码:228 / 239
页数:12
相关论文
共 27 条
[1]  
*AM NAT STAND SAF, Z13611993 ANSI
[2]  
[Anonymous], 1987, ACOUSTIC WAVES DEVIC
[3]   Characterization of post mortem arterial tissue using time-resolved photoacoustic spectroscopy at 436, 461 and 532 nm [J].
Beard, PC ;
Mills, TN .
PHYSICS IN MEDICINE AND BIOLOGY, 1997, 42 (01) :177-198
[4]  
DIEBOLD GJ, 1994, ACUSTICA, V80, P339
[5]   Laser optoacoustic imaging for breast cancer diagnostics: Limit of detection and comparison with X-ray and ultrasound imaging [J].
Esenaliev, RO ;
Karabutov, AA ;
Tittel, FK ;
Fornage, BD ;
Thomsen, SL ;
Stelling, C ;
Oraevsky, AA .
OPTICAL TOMOGRAPHY AND SPECTROSCOPY OF TISSUE: THEORY, INSTRUMENTATION, MODEL, AND HUMAN STUDIES II, PROCEEDINGS OF, 1997, 2979 :71-82
[6]   Real-time optoacoustic monitoring of temperature in tissues [J].
Esenaliev, RO ;
Oraevsky, AA ;
Larin, KV ;
Larina, IV ;
Motamedi, M .
LASER-TISSUE INTERACTION X: PHOTOCHEMICAL, PHOTOTHERMAL, AND PHOTOMECHANICAL, PROCEEDINGS OF, 1999, 3601 :268-275
[7]  
GUSEV VE, 1993, LASER OPTO ACOUSTICS
[8]   Photoacoustic blood cell detection and imaging of blood vessels in phantom tissue [J].
Hoelen, CGA ;
Pongers, R ;
Hamhuis, G ;
de Mul, FFM ;
Greve, J .
OPTICAL AND IMAGING TECHNIQUES FOR BIOMONITORING III, PROCEEDINGS OF, 1998, 3196 :142-153
[9]   Backward mode detection of laser-induced wide-band ultrasonic transients with optoacoustic transducer [J].
Karabutov, AA ;
Savateeva, EV ;
Podymova, NB ;
Oraevsky, AA .
JOURNAL OF APPLIED PHYSICS, 2000, 87 (04) :2003-2014
[10]  
Karabutov AA, 1996, APPL PHYS B-LASERS O, V63, P545