Missed subtle fractures on the trauma-meeting digital projector

被引:10
作者
Chellam, W. B. [1 ]
机构
[1] Hull Royal Infirm, Dept Trauma & Orthopaed, Yorkshire & Humber Deanery, 9th Floor Orthopaed Meeting Room,Anlaby Rd, Kingston Upon Hull HU3 2JZ, East Riding Of, England
来源
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED | 2016年 / 47卷 / 03期
关键词
PACS; Projector; Display; Sensitivity; Accuracy; Fracture; Hip; Neck of Femur; DISPLAY;
D O I
10.1016/j.injury.2015.11.001
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Introduction: Since the introduction of digital X-rays, many orthopaedic departments have used digital projection systems to display diagnostic images during discussion, there has been no published work directly comparing the sensitivity high resolution diagnostic monitors with standard digital projection systems in the context of orthopaedic injuries. Materials and methods: Participants were asked to review AP pelvic radiographs of non-displaced hip fractures on the department's digital projector and again on a diagnostic monitor, results were compared to determine if a true difference in sensitivity between the imaging modalities existed. Results: A significant difference in the sensitivity of the diagnostic monitor and meeting room projector was found, 0.85 vs 0.55, respectively (95% CI 0.78-0.89 vs 0.47-0.63); absolute difference 0.3 (95% CI 0.28-0.32, p <= 0.001). Inter-observer agreement was moderate. Discussion: A difference in sensitivity was demonstrated to a high level of statistical power, and a positive result on either modality was highly likely to represent a true fracture, however a fracture cannot be confidently excluded examining a single image using the digital projector alone. The study was limited to a single view of one particular fracture type and may not be generalisable to all types of subtle fracture; in addition, the retrospective nature of the image review means that the sensitivity figures cannot be applied to a presenting patient population. Conclusions: This study demonstrates a significant difference in sensitivity between the two display types which may have implications with regard to reducing delays and unnecessary further imaging if clinicians are not aware of this potential limitation. Clinicians, if clinically suspicious of a fracture should always seek to review the images on a validated PACS display device if a fracture is not seen on a nonvalidated device. Departments should evaluate their current equipment, consider what equipment is available, what is the most suitable equipment for the environment in which it is being used and what the potential implications for patient care may be as a result. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:674 / 676
页数:3
相关论文
共 8 条
[1]  
Board of the Faculty of Clinical Radiology, PACS QUAL ASS
[2]   Personal computer versus workstation display: Observer performance in detection of wrist fractures on digital radiographs [J].
Doyle, AJ ;
Le Fevre, J ;
Anderson, GD .
RADIOLOGY, 2005, 237 (03) :872-877
[3]   The effect of PACS on the practice of orthopaedic surgeons [J].
Fridell, Kent ;
Aspelin, Peter ;
Fellander-Tsai, Li ;
Lundberg, Nina .
JOURNAL OF TELEMEDICINE AND TELECARE, 2011, 17 (03) :137-141
[4]   Image and Diagnosis Quality of X-Ray Image Transmission via Cell Phone Camera: A Project Study Evaluating Quality and Reliability [J].
Goost, Hans ;
Witten, Johannes ;
Heck, Andreas ;
Hadizadeh, Dariusch R. ;
Weber, Oliver ;
Graeff, Ingo ;
Burger, Christof ;
Montag, Mareen ;
Koerfer, Felix ;
Kabir, Koroush .
PLOS ONE, 2012, 7 (10)
[5]   ROC analysis for diagnostic accuracy of fracture by using different monitors [J].
Liang, Zhigang ;
Li, Kuncheng ;
Yang, Xiaolin ;
Du, Xiangying ;
Liu, Jiabin ;
Zhao, Xin ;
Qi, Xiangdong .
JOURNAL OF DIGITAL IMAGING, 2006, 19 (03) :276-278
[6]   Changing from analog to digital images: Does it affect the accuracy of alignment measurements of the lower extremity? [J].
Lohman, Martina ;
Tallroth, Kaj ;
Kettunen, Jyrki A. ;
Remes, Ville .
ACTA ORTHOPAEDICA, 2011, 82 (03) :351-355
[7]  
National institute for clinical excellence, MAN HIP FRACT AD
[8]   Contrast-detail characteristic evaluations of several display devices [J].
Wang, JH ;
Anderson, J ;
Lane, T ;
Stetson, C ;
Moore, J .
JOURNAL OF DIGITAL IMAGING, 2000, 13 (02) :162-167