Ultrasound velocity and dual-energy X-ray absorptiometry in normal and pagetic bone

被引:16
作者
Pande, KC [1 ]
Bernard, J [1 ]
McCloskey, EV [1 ]
de Takats, D [1 ]
Kanis, JA [1 ]
机构
[1] Univ Sheffield, Sch Med, Dept Human Metab & Clin Biochem, WHO Collaborating Ctr Metab Bone Dis, Sheffield S10 2RX, S Yorkshire, England
关键词
Paget's disease of bone; ultrasound; bone densitometry; bone structure;
D O I
10.1016/S8756-3282(00)00247-7
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Bone affected by Paget's disease is known to be dense but more prone to fractures. It is proposed that dual-energy X-ray absorptiometry (DXA) and quantitative ultrasound (QUS) assess different aspects of the skeletal status. In this study, we used Paget's disease of the tibia as a model to explore this. Ten patients with Paget's disease affecting a single tibia were investigated with the normal side acting as the control within each individual. Tibial speed of sound (SOS) was: measured at the midpoint of the affected and control tibiae using a Soundscan 2000 (Myriad Ultrasound System, Rehovot, Israel) device. Bone mineral density (BMD) of the tibia was measured at a level corresponding to the site of the tibial ultrasound using a QDR-2000+ (Hologic, Inc., Waltham, MA), The mean bone area and estimated volume in the pagetic tibia was greater than that in the normal tibia (bone area: 25.10 +/- 8.00 vs, 20.23 +/- 5.43 cm(2), p = 0.017; estimated bone volume: 68.79 +/- 41.99 vs. 43.62 +/- 22.56 cm(3), p = 0.02), reflecting the bone expansion characteristic of Paget's disease. The bone mineral content (BMC) was more markedly increased in the pagetic tibia (27.38 +/- 12.98 vs. 14.39 +/- 6.14 g, p = 0.003) and, consequently, areal bone mineral density (BMD) was also markedly increased in the pagetic bone (1.09 +/- 0.38 vs, 0.77 +/- 0.44 g/cm(2), p = 0.018), There was no significant difference in the estimated volumetric BMD between the pagetic and the normal tibia (0.48 +/- 0.24 vs. 0.47 +/- 0.51 g/cm(3), p = 0.96). Tn contrast, the mean tibial SOS in the leg affected by Paget's disease was significantly lower than in the unaffected leg (3228 +/- 234 vs. 3840 +/- 164 m/sec, p < 0.001). When expressed as at score using the normal limb as reference, areal BMD was 0.72 SD higher in the affected limb, whereas tibial SOS was 3.72 SD lower. We conclude that tibial SOS detects important changes in bone quality in Pager's disease of bone, which are unrelated to calcium content. (C) 2000 by Elsevier Science Inc. All rights reserved.
引用
收藏
页码:525 / 528
页数:4
相关论文
共 28 条
[1]  
ABENDSCHEIN W, 1970, CLIN ORTHOP RELAT R, P294
[2]   ELASTIC PROPERTIES OF CANCELLOUS BONE - MEASUREMENT BY AN ULTRASONIC TECHNIQUE [J].
ASHMAN, RB ;
CORIN, JD ;
TURNER, CH .
JOURNAL OF BIOMECHANICS, 1987, 20 (10) :979-986
[3]   ELASTIC-MODULUS OF TRABECULAR BONE MATERIAL [J].
ASHMAN, RB ;
RHO, JY .
JOURNAL OF BIOMECHANICS, 1988, 21 (03) :177-181
[4]   A CONTINUOUS WAVE TECHNIQUE FOR THE MEASUREMENT OF THE ELASTIC PROPERTIES OF CORTICAL BONE [J].
ASHMAN, RB ;
COWIN, SC ;
VANBUSKIRK, WC ;
RICE, JC .
JOURNAL OF BIOMECHANICS, 1984, 17 (05) :349-361
[5]   ULTRASOUND ATTENUATION OF THE OS CALCIS IN WOMEN WITH OSTEOPOROSIS AND HIP-FRACTURES [J].
BARAN, DT ;
KELLY, AM ;
KARELLAS, A ;
GIONET, M ;
PRICE, M ;
LEAHEY, D ;
STEUTERMAN, S ;
MCSHERRY, B ;
ROCHE, J .
CALCIFIED TISSUE INTERNATIONAL, 1988, 43 (03) :138-142
[6]   Broadband ultrasound attenuation predicts fractures strongly and independently of densitometry in older women - A prospective study [J].
Bauer, DC ;
Gluer, CC ;
Cauley, JA ;
Vogt, TM ;
Ensrud, KE ;
Genant, HK ;
Black, DM .
ARCHIVES OF INTERNAL MEDICINE, 1997, 157 (06) :629-634
[7]   ULTRASONIC ANALYSIS OF THE YOUNG MODULUS OF CORTICAL BONE [J].
BONFIELD, W ;
TULLY, AE .
JOURNAL OF BIOMEDICAL ENGINEERING, 1982, 4 (01) :23-27
[8]   BONE LOSS AFTER TIBIAL FRACTURE [J].
EYRES, KS ;
KANIS, JA .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1995, 77B (03) :473-478
[9]   QUANTITATIVE ULTRASOUND OF THE TIBIA - A NOVEL-APPROACH FOR ASSESSMENT OF BONE STATUS [J].
FOLDES, AJ ;
RIMON, A ;
KEINAN, DD ;
POPOVTZER, MM .
BONE, 1995, 17 (04) :363-367
[10]   QUANTITATIVE ULTRASOUND [J].
FUERST, T ;
GLUER, CC ;
GENANT, HK .
EUROPEAN JOURNAL OF RADIOLOGY, 1995, 20 (03) :188-192