A multicomponent mobile phase utilizing ion-exchange, ion-exclusion, and ion-pairing principles for the rapid isocratic separation of anions in low explosives residue by ion chromatography (IC) has been developed. The notable feature of this system is that an ion-pairing reagent and an ion-exclusion reagent are combined in the same mobile phase. Contrary to expectation, these reagents act independently of each other in solution. The stock mobile-phase composition consisted of boric acid, D-gluconic acid, Lithium hydroxide, and glycerol. Tetrapropylammonium hydroxide, an ion-interaction reagent was used to achieve pH 8.5. Acetonitrile (ACN) was added to enhance resolution and octanesulfonic acid, an ion-exclusion reagent, was added to adjust the retention time of perchlorate, Separation of a mixture of anions common to low explosives residue was achieved in less than 16 min using a Waters IC-Pak Anion HR column, Optimization studies were performed by changing the concentration of the ACN and by altering the pH or the type of ion-interaction or -exclusion agents. Simulated case studies were performed using postblast residues from pipe bombs. The results show this method to be a valid and reproducible procedure for forensic casework analysis. The practical significance of this system is that a reduction in the analysis time and an improvement in efficiency of late-eluting peaks can be achieved without resorting to gradient elution techniques. For the analysis of anions detected in explosives residue, the Waters IC-Pak Anion HR column has proven to be a suitable replacement for the Vydac 300IC405 column, which has been discontinued by the manufacturer.
引用
收藏
页码:2302 / 2307
页数:6
相关论文
共 28 条
[1]  
[Anonymous], 1998, FORENSIC INVEST EXPL
[2]  
Bender E. C., 1998, FORENSIC INVESTIGATI, P343
[3]  
BEVERIDGE AD, 1983, P INT S AN DET EXPL, P53
[4]   DYNAMICALLY COATED COLUMNS AND CONDUCTIVITY DETECTION FOR TRACE DETERMINATION OF ORGANIC-ANIONS BY ION CHROMATOGRAPHY [J].
CASSIDY, RM ;
ELCHUK, S .
JOURNAL OF CHROMATOGRAPHY, 1983, 262 (JUN) :311-315
[6]  
DASGUPTA PK, 1987, ION CHROMATOGRAPHY, P253
[7]  
Dean J.A., 1985, LANGES HDB CHEM, V13
[8]   Novel electrolyte for the analysis of cations in low explosive residue by capillary electrophoresis [J].
Doyle, JM ;
McCord, BR .
JOURNAL OF CHROMATOGRAPHY B, 1998, 714 (01) :105-111
[9]  
HADDAD PR, 1992, J CHROMATOGR LIB B, V51, pB42
[10]   ANALYSIS OF COMMERCIAL EXPLOSIVES BY SINGLE-COLUMN ION CHROMATOGRAPHY [J].
HENDERSON, IK ;
SAARINORDHAUS, R .
JOURNAL OF CHROMATOGRAPHY, 1992, 602 (1-2) :149-154