An in vivo comparison of two circumferential penile strain gauges: The introduction of a new calibration method

被引:12
作者
Janssen, E [1 ]
Vissenberg, M [1 ]
Visser, S [1 ]
Everaerd, W [1 ]
机构
[1] UNIV AMSTERDAM,DEPT CLIN PSYCHOL,NL-1018 WB AMSTERDAM,NETHERLANDS
关键词
male sexual arousal; penile erection; penile strain gauge; calibration; methodology; psychophysiology;
D O I
10.1111/j.1469-8986.1997.tb02147.x
中图分类号
B84 [心理学];
学科分类号
04 ; 0402 ;
摘要
This study assessed the comparability of two types of penile strain gauges using both a circular and a newly developed oval calibration device. A group of 25 sexually functional participants placed both an electromechanical and an indium/gallium-in-rubber strain gauge on the penis and viewed an erotic film. The electromechanical gauge as calibrated on the circular device resulted in greater penile circumference changes than the indium/gallium-in-rubber gauge. Mean circumference changes were not different for the two strain gauges when the oval calibration device was used. The use of an oval calibration device improves ecological validity of calibration of penile strain gauges. Standard inclusion of this method in studies on male sexual response will increase comparability of research findings.
引用
收藏
页码:717 / 720
页数:4
相关论文
共 15 条
[1]   A SIMPLE TRANSDUCER FOR MEASURING PENILE ERECTION WITH COMMENTS ON ITS USE IN TREATMENT OF SEXUAL DISORDERS [J].
BANCROFT, JH ;
JONES, HG ;
PULLAN, BR .
BEHAVIOUR RESEARCH AND THERAPY, 1966, 4 (03) :239-&
[2]  
BARLOW DH, 1970, J APPL BEHAV ANAL, V6, P355
[3]  
Dixon WJ, 1990, BMDP STAT SOFTWARE
[4]  
EARLS CM, 1981, BEHAV ASSESS, V3, P145
[5]   RELIABILITY AND VALIDITY OF THE MERCURY-IN-RUBBER STRAIN-GAUGE MEASURE OF PENILE CIRCUMFERENCE [J].
FARKAS, GM ;
EVANS, IM ;
SINE, LF ;
EIFERT, G ;
WITTLIEB, E ;
VOGELMANNSINE, S .
BEHAVIOR THERAPY, 1979, 10 (04) :555-561
[6]  
GEER JH, 1990, PRINCIPLES PSYCHOPHY, P599
[7]   A SIMPLE AND INEXPENSIVE TRANSDUCER FOR QUANTITATIVE MEASUREMENTS OF PENILE ERECTION DURING SLEEP [J].
KARACAN, I .
BEHAVIOR RESEARCH METHODS & INSTRUMENTATION, 1969, 1 (07) :251-&
[8]   COMPARISON OF MEASUREMENT CHARACTERISTICS OF 2 CIRCUMFERENTIAL PENILE TRANSDUCERS [J].
LAWS, DR .
ARCHIVES OF SEXUAL BEHAVIOR, 1977, 6 (01) :45-51
[9]   LINEARITY OF THE ELECTROMECHANICAL PENILE PLETHYSMOGRAPHS OUTPUT AT LARGE EXPANSIONS [J].
RICHARDS, JC ;
KALUCY, RS ;
WOOD, MM ;
MARSHALL, VR .
JOURNAL OF SEX RESEARCH, 1990, 27 (02) :283-287
[10]   A CONTROLLED INVESTIGATION INTO THE MEASUREMENT PROPERTIES OF 2 CIRCUMFERENTIAL PENILE STRAIN-GAUGES [J].
RICHARDS, JC ;
BRIDGER, BA ;
WOOD, MM ;
KALUCY, RS ;
MARSHALL, VR .
PSYCHOPHYSIOLOGY, 1985, 22 (05) :568-571