New femoral designs - Do they influence stress shielding?

被引:159
作者
Glassman, A. H.
Bobyn, J. D.
Tanzer, M.
机构
[1] Ohio State Univ, Dept Orthopaed Surg, Columbus, OH 43210 USA
[2] Ohio State Univ, Grant Med Ctr, Columbus, OH 43210 USA
[3] McGill Univ, Montreal Gen Hosp, Div Orthopaed, Montreal, PQ H3G 1A4, Canada
关键词
D O I
10.1097/01.blo.0000246541.41951.20
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Virtually all contemporary cementless femoral hip stems are designed with the goals of achieving immediate and long-term stability, restoring hip mechanics, and minimizing thigh pain. However, the incorporation of features specifically intended to minimize stress-mediated bone resorption (stress shielding) has been variable. Attempts to reduce bone loss through stem design have yielded inconsistent results and, in certain instances, early and catastrophic failure. Prior beliefs regarding the determinants of stress shielding were based upon the qualitative assessment of bone loss using plain radiographs. These are being challenged, particularly with regard to the role of porous coating level. This is in large part due to the refinement and widespread availability of dual-energy xray absorptiometry (DEXA), which allows quantitative assessment of bone mineral density both pre- and postoperatively. The available evidence indicates stem stiffness plays a dominant role. Progressive bone loss through stress shielding has potentially dire consequences. While such problems have not manifested as severe or widespread clinical issues, the preservation of femoral bone stock is an important and desirable goal.
引用
收藏
页码:64 / 74
页数:11
相关论文
共 60 条
[1]
Early failure of a carbon-fiber composite femoral component [J].
Allcock, S ;
Ali, MA .
JOURNAL OF ARTHROPLASTY, 1997, 12 (03) :356-358
[2]
BLOEBAUM RD, 1993, J ARTHROPLASTY, V8, P203, DOI 10.1016/S0883-5403(09)80014-4
[3]
BOBYN JD, 1992, CLIN ORTHOP RELAT R, P79
[4]
BOBYN JD, 1990, CLIN ORTHOP RELAT R, P196
[5]
Böhler M, 2000, ORTHOPEDICS, V23, P1261
[6]
Changes in bone mineral density in the proximal femur after cementless total hip arthroplasty - A five-year longitudinal study [J].
Brodner, W ;
Bitzan, P ;
Lomoschitz, F ;
Krepler, P ;
Jankovsky, R ;
Lehr, S ;
Kainberger, F ;
Gottsauner-Wolf, F .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2004, 86B (01) :20-26
[7]
Long-term clinical consequences of stress-shielding after total hip arthroplasty without cement [J].
Bugbee, WD ;
Culpepper, WJ ;
Engh, CA ;
Engh, CA .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1997, 79A (07) :1007-1012
[8]
Cameron H U, 1993, J Arthroplasty, V8, P239, DOI 10.1016/S0883-5403(06)80084-7
[9]
Modeling of bone around hydroxyapatite-coated femoral stems [J].
DAntonio, JA ;
Township, M ;
Capello, WN ;
Manley, MT .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1996, 78A (08) :1226-1234
[10]
Bilateral total hip arthroplasty comparing hydroxyapatite coating to porous-coated fixation [J].
Dorr, LD ;
Wan, ZN ;
Song, M ;
Ranawat, A .
JOURNAL OF ARTHROPLASTY, 1998, 13 (07) :729-736