Selectivity enhancement of anion-responsive electrodes by pulsed chronopotentiometry

被引:34
作者
Gemene, Kebede L. [1 ]
Shvarev, Alexey [1 ]
Bakker, Eric [1 ]
机构
[1] Purdue Univ, Dept Chem, W Lafayette, IN 47907 USA
关键词
ion-selective electrodes; selectivity enhancement; clinical analysis; anion detection; solvent polymeric membrane;
D O I
10.1016/j.aca.2006.09.042
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A large and robust selectivity improvement of ion-selective electrodes is presented for the measurement of abundant ions. An improvement in selectivity by more than two orders of magnitude has been attained for the hydrophilic chloride ions measured in a dilute background of the lipophilic ions perchlorate and salicylate in a pulsed chronopotentiometric measurement mode. This is attributed to a robust kinetic discrimination of the dilute lipophilic ions in this measuring mode, which is not possible to achieve in classical potentiometry. Maximum tolerable concentrations of the interfering ions are found to be on the order of 30 mu M before causing substantial changes in potential. As an example of practical relevance, the robust detection of chloride in 72 mu M salicylate (reflecting 1: 10 diluted blood) with a detection limit of 0.5 mM chloride is demonstrated. Corresponding potentiometric sensors did not give a useful chloride response under these conditions. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:190 / 196
页数:7
相关论文
共 29 条
[1]  
[Anonymous], 1976, PURE APPL CHEM, V48, P127, DOI DOI 10.1351/PAC197648010127
[2]   ANION-SELECTIVE MEMBRANE ELECTRODES BASED ON METALLOPORPHYRINS - THE INFLUENCE OF LIPOPHILIC ANIONIC AND CATIONIC SITES ON POTENTIOMETRIC SELECTIVITY [J].
BAKKER, E ;
MALINOWSKA, E ;
SCHILLER, RD ;
MEYERHOFF, ME .
TALANTA, 1994, 41 (06) :881-890
[3]   Determination of unbiased selectivity coefficients of neutral carrier-based cation-selective electrodes [J].
Bakker, E .
ANALYTICAL CHEMISTRY, 1997, 69 (06) :1061-1069
[4]   SELECTIVITY OF POLYMER MEMBRANE-BASED ION-SELECTIVE ELECTRODES - SELF-CONSISTENT MODEL DESCRIBING THE POTENTIOMETRIC RESPONSE IN MIXED ION SOLUTIONS OF DIFFERENT CHARGE [J].
BAKKER, E ;
MERUVA, RK ;
PRETSCH, E ;
MEYERHOFF, ME .
ANALYTICAL CHEMISTRY, 1994, 66 (19) :3021-3030
[5]   Tripodal ionophore with sulfate recognition properties for anion-selective electrodes [J].
Berrocal, MJ ;
Cruz, A ;
Badr, IHA ;
Bachas, LG .
ANALYTICAL CHEMISTRY, 2000, 72 (21) :5295-5299
[6]   Carbonate ion-selective electrode with reduced interference from salicylate [J].
Bobacka, J ;
Maj-Zurawska, M ;
Lewenstam, A .
BIOSENSORS & BIOELECTRONICS, 2003, 18 (2-3) :245-253
[7]   Carrier-based ion-selective electrodes and bulk optodes. 2. Ionophores for potentiometric and optical sensors [J].
Buhlmann, P ;
Pretsch, E ;
Bakker, E .
CHEMICAL REVIEWS, 1998, 98 (04) :1593-1687
[8]   Potentiometric polymeric membrane electrodes for measurement of environmental samples at trace levels:: New requirements for selectivities and measuring protocols, and comparison with ICPMS [J].
Ceresa, A ;
Bakker, E ;
Hattendorf, B ;
Günther, D ;
Pretsch, E .
ANALYTICAL CHEMISTRY, 2001, 73 (02) :343-351
[9]   ASYMMETRIC CELLULOSE-ACETATE MEMBRANE-BASED CARBONATE-SELECTIVE AND CHLORIDE-SELECTIVE ELECTRODES [J].
CHA, MJ ;
SHIN, JH ;
OH, BK ;
KIM, CY ;
CHA, GS ;
SHIN, DS ;
KIM, B .
ANALYTICA CHIMICA ACTA, 1995, 315 (03) :311-319
[10]   INFLUENCE OF PORPHYRIN STRUCTURE ON ANION SELECTIVITIES OF MANGANESE(III) PORPHYRIN BASED MEMBRANE ELECTRODES [J].
CHANIOTAKIS, NA ;
CHASSER, AM ;
MEYERHOFF, ME ;
GROVES, JT .
ANALYTICAL CHEMISTRY, 1988, 60 (02) :185-188