Second harmonic imaging of intrinsic signals in muscle fibers in situ

被引:89
作者
Both, M [1 ]
Vogel, M [1 ]
Friedrich, O [1 ]
von Wegner, F [1 ]
Künsting, T [1 ]
Fink, RHA [1 ]
Uttenweiler, D [1 ]
机构
[1] Heidelberg Univ, Inst Physiol & Pathophysiol, Med Biophys Unit, D-69120 Heidelberg, Germany
关键词
second harmonic generation; intrinsic signal; muscle; actin; myosin; motor proteins;
D O I
10.1117/1.1783354
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
We use second harmonic generation (SHG) imaging to study and quantify a strong intrinsic SHG signal in skeletal muscle fiber preparations and single isolated myofibrils. The intrinsic signal follows the striation pattern of the muscle cells and is positioned at the sarcomeric location of the myosin filaments. Interestingly, the signal is enhanced at the region where the myosin heads are located on the myosin filaments. As the intrinsic signal reflects the subcellular structure in an accurate way, SHG can be used for noninvasive high resolution structural imaging without exogenous labels in living muscle cells. This may be very important for detecting changes in myofibrillar organization occurring under pathophysiological conditions, e.g., in cardiac and skeletal myopathies. Due to the strong dependency of SHG on orientation and symmetries of the tissue, it may allow the study of dynamic interactions between the contractile proteins actin and myosin during force production and muscle shortening. Furthermore, SHG imaging can be combined with other nonlinear microscopical techniques, such as laser scanning multiphoton fluorescence microscopy, to simultaneously measure other dynamic cellular processes, representing a complementary method and extending the range of nonlinear microscopical methods. (C) 2004 society of Photo-Optical Instrumentation Engineers.
引用
收藏
页码:882 / 892
页数:11
相关论文
共 30 条
[1]   Second harmonic generation imaging in muscle fibers [J].
Both, M ;
Vogel, M ;
Fink, RHA ;
Uttenweiler, D .
CONFOCAL, MULTIPHOTON, AND NONLINEAR MICROSCOPIC IMAGING, 2003, 5139 :112-120
[2]  
BOTH M, 2002, PFLUGERS ARCH, V443, P5336
[3]   High-resolution nonlinear optical imaging of live cells by second harmonic generation [J].
Campagnola, PJ ;
Wei, MD ;
Lewis, A ;
Loew, LM .
BIOPHYSICAL JOURNAL, 1999, 77 (06) :3341-3349
[4]   Three-dimensional high-resolution second-harmonic generation imaging of endogenous structural proteins in biological tissues [J].
Campagnola, PJ ;
Millard, AC ;
Terasaki, M ;
Hoppe, PE ;
Malone, CJ ;
Mohler, WA .
BIOPHYSICAL JOURNAL, 2002, 82 (01) :493-508
[5]   2-PHOTON LASER SCANNING FLUORESCENCE MICROSCOPY [J].
DENK, W ;
STRICKLER, JH ;
WEBB, WW .
SCIENCE, 1990, 248 (4951) :73-76
[6]   SCANNING COHERENT ANTI-STOKES RAMAN MICROSCOPE [J].
DUNCAN, MD ;
REINTJES, J ;
MANUCCIA, TJ .
OPTICS LETTERS, 1982, 7 (08) :350-352
[7]  
FORSTER T, 1948, ANN PHYS, V2, P57
[8]   CONNECTIVE-TISSUE POLARITY - OPTICAL 2ND-HARMONIC MICROSCOPY, CROSSED-BEAM SUMMATION, AND SMALL-ANGLE SCATTERING IN RAT-TAIL TENDON [J].
FREUND, I ;
DEUTSCH, M ;
SPRECHER, A .
BIOPHYSICAL JOURNAL, 1986, 50 (04) :693-712
[9]   Calcium currents during contraction and shortening in enzymatically isolated murine skeletal muscle fibres [J].
Friedrich, O ;
Ehmer, T ;
Fink, RHA .
JOURNAL OF PHYSIOLOGY-LONDON, 1999, 517 (03) :757-770
[10]   STRUCTURAL BASIS OF THE CROSS-STRIATIONS IN MUSCLE [J].
HANSON, J ;
HUXLEY, HE .
NATURE, 1953, 172 (4377) :530-532