Controlled delivery of therapeutics from microporous membranes .1. Fabrication and characterization of microporous polyurethane membranes containing polymeric microspheres

被引:8
作者
Kreitz, MR [1 ]
Webber, WL [1 ]
Galletti, PM [1 ]
Mathiowitz, E [1 ]
机构
[1] BROWN UNIV,DEPT MOL PHARMACOL & BIOTECHNOL,ARTIFICAL ORGANS LAB,PROVIDENCE,RI 02912
关键词
polyurethane; Cardiothane(TM); poly(D; L-lactide-co-glycolide; 50:50); microspheres; vascular graft; microporous membrane;
D O I
10.1016/S0142-9612(96)00153-6
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This paper describes a process for the inclusion of polymer microspheres in microporous polyurethane tubes and membranes. These composites were fabricated via a spray, phase-inversion technique using Cardiothane(TM) 51, a medical grade polyurethane, and either spray-dried poly(D,L-lactide-co-glycolide 50:50) microspheres or commercially available fluorescent polystyrene-latex microspheres. Characterization of the polyurethane membranes was performed using Fourier-transform infrared spectroscopy, differential scanning calorimetry, dynamic mechanical analysis, hydraulic permeability testing, scanning electron microscopy, and visible and fluorescence light microscopy. The results indicated the feasibility of layering microspheres throughout the microporous membrane or wall of the microporous tube, and the potential of such composite structures for local delivery of bioactive substances. (C) 1997 Elsevier Science Limited.
引用
收藏
页码:597 / 603
页数:7
相关论文
共 16 条
[1]  
*ARR INT, 1995, BIOM POLYM APPL FABR
[2]   DYNAMIC COMPLIANCE OF ARTERIAL GRAFTS [J].
BAIRD, RN ;
KIDSON, IG ;
LITALIEN, GJ ;
ABBOTT, WM .
AMERICAN JOURNAL OF PHYSIOLOGY, 1977, 233 (05) :H568-H572
[3]  
ESQUIVEL CO, 1984, SURGERY, V95, P102
[4]   WHY SMALL CALIBER VASCULAR GRAFTS FAIL - A REVIEW OF CLINICAL AND EXPERIMENTAL EXPERIENCE AND THE SIGNIFICANCE OF THE INTERACTION OF BLOOD AT THE INTERFACE [J].
ESQUIVEL, CO ;
BLAISDELL, FW .
JOURNAL OF SURGICAL RESEARCH, 1986, 41 (01) :1-15
[5]   POROUS POLYURETHANE TUBES AS VASCULAR GRAFT [J].
FUJIMOTO, K ;
MINATO, M ;
MIYAMOTO, S ;
KANEKO, T ;
KIKUCHI, H ;
SAKAI, K ;
OKADA, M ;
IKADA, Y .
JOURNAL OF APPLIED BIOMATERIALS, 1993, 4 (04) :347-354
[6]  
GREISLER HP, 1992, SURGERY, V112, P244
[7]  
GREISLER HP, 1989, ARCH SURG-CHICAGO, V124, P429
[8]   COMPLIANCE AS A FACTOR EFFECTING PATENCY OF A COPOLYURETHANE VASCULAR GRAFT [J].
LYMAN, DJ ;
FAZZIO, FJ ;
VOORHEES, H ;
ROBINSON, G ;
ALBO, D .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1978, 12 (03) :337-345
[9]   THE USE OF BIODEGRADABLE AMIKACIN MICROSPHERES TO PREVENT VASCULAR GRAFT INFECTION [J].
NEY, AL ;
GRANJA, JA ;
SCHUSTER, PA ;
TSUKAYAMA, DT ;
JACOBS, DM ;
BUBRICK, MP .
JOURNAL OF SURGICAL RESEARCH, 1994, 57 (06) :698-705
[10]  
OKOSHI T, 1991, ASAIO T, V37, P7480