Effectiveness of implantable cardioverter-defibrillators in patients with ischemic heart disease and left ventricular dysfunction

被引:12
作者
Chan, Paul S.
Chow, Theodore
Kereiakes, Dean
Schloss, Edward J.
Waller, Theodore
Eagle, Kim
Hayward, Rodney A.
Vijan, Sandeep
机构
[1] Univ Michigan, Div Cardiol, Ann Arbor, MI 48109 USA
[2] Univ Michigan, Dept Internal Med, Ann Arbor, MI 48109 USA
[3] Ann Arbor Vet Affair Med Ctr, Hlth Serv Res & Dev Ctr Excellence, Ann Arbor, MI USA
[4] Ohio Heart & Vasc Ctr, Cincinnati, OH USA
[5] Lindner Clin Trials Ctr, Cincinnati, OH USA
关键词
D O I
10.1001/archinte.166.20.2228
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Implantable cardioverter-defibrillators (ICDs) have been shown in primary prevention efficacy trials to reduce mortality in patients with ischemic heart disease and left ventricular dysfunction. To investigate the generalizabilty of this mortality reduction, we examined the effectiveness of ICDs in clinical practice. Methods: We developed a prospective multicenter cohort of 770 patients with ischemic left ventricular dysfunction ( ejection fraction <= 35%) and without a history of ventricular arrhythmia, of whom 395 (52%) received ICDs. Mean +/- SD follow-up was 27 +/- 12 months. We assessed the degree to which ICDs decreased mortality risk using Cox proportional hazards analyses that controlled for clinical predictors of death, receipt of ICD (a propensity score analysis), and predictors of arrhythmic death (including electrophysiologic variables). Results: Multivariate Cox analyses showed that those with ICDs had significantly lower all-cause mortality ( hazard ratio [HR], 0.53; 95% confidence interval [CI], 0.330.86). This mortality reduction was mediated through dramatically lower arrhythmia-related mortality (HR, 0.35; 95% CI, 0.17-0.73), with no significant effect on cardiovascular nonarrhythmic (HR, 0.81; 95% CI, 0.34-1.96) and noncardiovascular (HR, 0.76; 95% CI, 0.29-2.05) mortality. No differences were found between the ICD and non-ICD groups for a composite outcome of all-cause mortality, appropriate ICD shocks, or documented symptomatic ventricular arrhythmia, which suggests that the 2 groups had similar baseline risk for life-threatening arrhythmic events (HR, 0.96; 95% CI, 0.63-1.45). Conclusion: In clinical practice, ICDs appear to reduce all-cause and arrhythmic rates of mortality at levels similar to those found in primary prevention trials.
引用
收藏
页码:2228 / 2233
页数:6
相关论文
共 21 条
  • [1] The relation between patients' outcomes and the volume of cardioverter-defibrillator implantation procedures performed by physicians treating medicare beneficiaries
    Al-Khatib, SM
    Lucas, FL
    Jollis, JG
    Malenka, DJ
    Wennberg, DE
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2005, 46 (08) : 1536 - 1540
  • [2] Clinical and economic implications of the multicenter automatic defibrillator implantation trial-II
    Al-Khatib, SM
    Anstrom, KJ
    Eisenstein, EL
    Peterson, ED
    Jollis, JG
    Mark, DB
    Li, Y
    O'Connor, CM
    Shaw, LK
    Califf, RM
    [J]. ANNALS OF INTERNAL MEDICINE, 2005, 142 (08) : 593 - 600
  • [3] Amiodarone or an implantable cardioverter-defibrillator for congestive heart failure
    Bardy, GH
    Lee, KL
    Mark, DB
    Poole, JE
    Packer, DL
    Boineau, R
    Domanski, M
    Troutman, C
    Anderson, J
    Johnson, G
    McNulty, SE
    Clapp-Channing, N
    Davidson-Ray, LD
    Fraulo, ES
    Fishbein, DP
    Luceri, RM
    Ip, JH
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2005, 352 (03) : 225 - 237
  • [4] Interpretation and classification of microvolt T wave alternans tests
    Bloomfield, DM
    Hohnloser, SH
    Cohen, RJ
    [J]. JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2002, 13 (05) : 502 - 512
  • [5] A randomized study of the prevention of sudden death in patients with coronary artery disease
    Buxton, AE
    Lee, KL
    Fisher, JD
    Josephson, ME
    Prystowsky, EN
    Hafley, G
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1999, 341 (25) : 1882 - 1890
  • [6] *CDCP, 2003, NAT DEATH IND US MAN
  • [7] Cost-effectiveness of a microvolt T-wave alternans screening strategy for implantable cardioverter-defibrillator placement in the MADIT-II-eligible population
    Chan, Paul S.
    Stein, Kenneth
    Chow, Theodore
    Fendrick, Mark
    Bigger, J. Thomas
    Vijan, Sandeep
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 48 (01) : 112 - 121
  • [8] Mortality reduction by Implantable cardloverter-defibrillators in high-risk patients with heart failure, ischemic heart disease, and new-onset ventricular arrhythmia - An effectiveness study
    Chan, PS
    Hayward, RA
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2005, 45 (09) : 1474 - 1481
  • [9] *CTR MED MED SERV, 2004, MED DRAFT NAT COV IM
  • [10] CLINICAL CLASSIFICATION OF CARDIAC DEATHS
    HINKLE, LE
    THALER, HT
    [J]. CIRCULATION, 1982, 65 (03) : 457 - 464