A 5.2 mW Self-Configured Wearable Body Sensor Network Controller and a 12 μW Wirelessly Powered Sensor for a Continuous Health Monitoring System

被引:151
作者
Yoo, Jerald [1 ]
Yan, Long [1 ]
Lee, Seulki [1 ]
Kim, Yongsang [1 ]
Yoo, Hoi-Jun [1 ]
机构
[1] Korea Adv Inst Sci & Technol, Dept Elect Engn, Taejon 305701, South Korea
关键词
Body sensor network; continuous health monitoring; dry electrode; electrocardiogram (ECG); planar-fashionable circuit board (P-FCB); rectifier; self-configuration; wearable network; wireless power transmission;
D O I
10.1109/JSSC.2009.2034440
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A self-configured body sensor network controller and a high efficiency wirelessly powered sensor are presented for a wearable, continuous health monitoring system. The sensor chip harvests its power from the surrounding health monitoring band using an Adaptive Threshold Rectifier (ATR) with 54.9% efficiency, and it consumes 12 mu W to implement an electrocardiogram (ECG) analog front-end and an ADC. The ATR is implemented with a standard CMOS process for low cost. The adhesive bandage type sensor patch is composed of the sensor chip, a Planar-Fashionable Circuit Board (P-FCB) inductor, and a pair of dry P-FCB electrodes. The dry P-FCB electrodes enable long term monitoring without skin irritation. The network controller automatically locates the sensor position, configures the sensor type (self-configuration), wirelessly provides power to the configured sensors, and transacts data with only the selected sensors while dissipating 5.2 mW at a single 1.8 V supply. Both the sensor and the health monitoring band are implemented using P-FCB for enhanced wearability and for lower production cost. The sensor chip and the network controller chip occupy 4.8 mm(2) and 15.0 mm(2), respectively, including pads, in standard 0.18 mu m 1P6M CMOS technology.
引用
收藏
页码:178 / 188
页数:11
相关论文
共 25 条
[1]  
ALLIANCE Z, 2007, ZIGBEE WHITE PAPER
[2]   A CMOS nested-chopper instrumentation amplifier with 100-nV offset [J].
Bakker, A ;
Thiele, K ;
Huijsing, JH .
IEEE JOURNAL OF SOLID-STATE CIRCUITS, 2000, 35 (12) :1877-1883
[3]   Contact dermatitis from propylene glycol in ECG electrodes, complicated by medicament allergy [J].
Connolly, M ;
Buckley, DA .
CONTACT DERMATITIS, 2004, 50 (01) :42-42
[4]   Usefulness of ambulatory 7-day ECG monitoring for the detection of atrial fibrillation and flutter after acute stroke and transient ischemic attack [J].
Jabaudon, D ;
Sztajzel, J ;
Sievert, K ;
Landis, T ;
Sztajzel, R .
STROKE, 2004, 35 (07) :1647-1651
[5]  
Kang T.- H., 2008, IEEE T BIOMEDICAL EN, V55
[6]  
Kim H, 2008, 2008 IEEE INTERNATIONAL CONFERENCE ON SYSTEM OF SYSTEMS ENGINEERING (SOSE), P159
[7]   A Low Cost Quadratic Level ECG Compression Algorithm and Its Hardware Optimization for Body Sensor Network System [J].
Kim, Hyejung ;
Kim, Yongsang ;
Yoo, Hoi-Jun .
2008 30TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-8, 2008, :5490-5493
[8]  
KIM Y, IEEE T ADV PACKAGING
[9]   Health monitoring in the home of the future [J].
Korhonen, I ;
Pärkkä, J ;
Van Gils, M .
IEEE ENGINEERING IN MEDICINE AND BIOLOGY MAGAZINE, 2003, 22 (03) :66-73
[10]  
LAUTERBACH C., 2002, AV S