Root-end cavity preparation using the MicroMega sonic Retro-prep Tip(TM). SEM analysis

被引:19
作者
Lloyd, A [1 ]
Jaunberzins, A [1 ]
Dummer, PMH [1 ]
Bryant, S [1 ]
机构
[1] UNIV WALES COLL CARDIFF, COLL MED, SCH DENT, DEPT RESTORAT DENT, CARDIFF CF4 4XY, S GLAM, WALES
关键词
endodontic surgery; marginal chipping; root-end resection; root-end cavity; Retro-prep tip; root-face cracking; sonic;
D O I
10.1111/j.1365-2591.1996.tb01388.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The objective of this laboratory study was to compare root-end cavities prepared with sonic Retro-prep tips in a MM1500 Sonic Air handpiece with those created by burs in a conventional handpiece. A total of 80 single-rooted extracted human teeth with mature apices and straight canals were included in the study. four groups of 20 extracted teeth were prepared as follows: I, a 3-4 mm root-end resection perpendicular to the long axis of the root, with a size 40 sonic Retro-prep tip creating an apical cavity 3 mm into root canal system; II, a 45 degrees bevel of the root-face removing a 3-4 mm root segment and root-end preparation as per group I; III, root-end resection as per group I, with an apical cavity prepared using a size 010 inverted cone bur 3 mm down the long axis of the root; IV, resection as per group II, followed by an apical cavity preparation with a size 010 inverted cone bur 3 mm into the root canal system. The apical root portion and root-end cavities were replicated and prepared for SEM analysis at X 20 and X 80 magnification. The degree of chipping associated with the margin of the root-end cavities, as evaluated with a standard grading system, and the incidence of root-face cracks were noted. Marginal chipping of root-end cavities prepared using sonic instrumentation was significantly worse than that produced by burs (P<0.001). Perpendicular root-end resections showed significantly better scores than bevelled root-end resections (P<0.005). The incidence of root-face cracking was low with no significant difference between the experimental groups.
引用
收藏
页码:295 / 301
页数:7
相关论文
共 36 条
[1]  
Allison D A, 1979, J Endod, V5, P298, DOI 10.1016/S0099-2399(79)80078-3
[2]   RETROGRADE AMALGAM PROCEDURES FOR MANDIBULAR POSTERIOR TEETH [J].
BLOCK, RM ;
BUSHELL, A .
JOURNAL OF ENDODONTICS, 1982, 8 (03) :107-112
[3]  
Cambruzzi J V, 1983, J Can Dent Assoc, V49, P61
[4]  
Carr G, 1992, Endod Rep, V7, P6
[5]  
Carr G B, 1992, J Calif Dent Assoc, V20, P55
[6]  
CARR GB, 1992, ENDODONTIC REPORT, V20, P55
[7]  
Carr GB, 1994, PATHWAYS PULP, V6th, P531
[8]  
COFFAE KP, 1975, J ENDODONT, V14, P527
[9]   ASSESSMENT OF A NON-ELASTOMERIC POLYMER FOR REPLICATION OF TOOTH SURFACE INVIVO [J].
COWELL, CR ;
SAXTON, CA .
JOURNAL OF DENTISTRY, 1978, 6 (03) :210-216
[10]  
DUMMER PMH, 1993, INT ENDOD J, V26, P159