Detection of choledocholithiasis with MR cholangiography: Comparison of three-dimensional fast spin-echo and single- and multisection half-Fourier rapid acquisition with relaxation enhancement sequences

被引:76
作者
Soto, JA
Barish, MA
Alvarez, O
Medina, S
机构
[1] Univ Antioquia, Hop St Vincent de Paul, Dept Radiol, Medellin, Colombia
[2] Univ Antioquia, Hop St Vincent de Paul, Dept Gastroenterol, Medellin, Colombia
[3] Boston Med Ctr, Dept Radiol, Boston, MA USA
[4] Childrens Hosp, Med Ctr, Dept Radiol, Cincinnati, OH 45229 USA
关键词
bile ducts; calculi; MR; stenosis or obstruction; endoscopic retrograde cholangiopancreatography (ERCP); magnetic resonance (MR); comparative studies; half-Fourier-imaging;
D O I
10.1148/radiology.215.3.r00ma12737
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To compare the performance of three pulse sequences commonly used at magnetic resonance (MR) cholangiography in the diagnosis of choledocholithiasis. MATERIALS AND METHODS: MR cholangiography was performed in 57 patients who were suspected of having choledocholithiasis and referred for endoscopic retrograde cholangiography. Non-breath-hold three-dimensional fast spin-echo, breath-hold single-section half-fourier rapid acquisition with relaxation enhancement (RARE), and breath-hold multisection half-fourier RARE sequences were compared. Two radiologists independently interpreted the MR cholangiograms. Evaluated diagnostic performance parameters included sensitivity, specificity, receiver operating characteristic (ROC) curves, and interobserver agreement (kappa statistics). Endoscopic retrograde cholangiography was the standard of reference. RESULTS: Eight patients were excluded because of incomplete MR examinations (n = 4) or failure in the cannulation of the bile duct at retrograde cholangiography (n = 4). In 49 patients, the three MR cholangiographic sequences were completed successfully. In 24 (49%) of these patients, retrograde cholangiography demonstrated stones. Sensitivity and specificity of MR cholangiography exceeded 90%, and the area under the ROC curve was greater than 0.95 for both radiologists and for the three sequences. Interobserver agreement for presence of bile duct stones was at least 0.80 (very good) for the three sequences. CONCLUSION: The three MR cholangiographic sequences had similarly high sensitivities and specificities for the detection of choledocholithiasis.
引用
收藏
页码:737 / 745
页数:9
相关论文
共 34 条
[1]  
AGRESTI A, 1990, CATEGORICAL DATA ANA, P366
[2]   MR-CHOLANGIOPANCREATOGRAPHY - EFFICACY OF 3-DIMENSIONAL TURBO SPIN-ECHO TECHNIQUE [J].
BARISH, MA ;
YUCEL, EK ;
SOTO, JA ;
CHUTTANI, R ;
FERRUCCI, JT .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1995, 165 (02) :295-300
[3]   MR cholangiopancreatography: Techniques and clinical applications [J].
Barish, MA ;
Soto, JA .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1997, 169 (05) :1295-1303
[4]   Choledocholithiasis and bile duct stenosis: Diagnostic accuracy of MR cholangiopancreatography [J].
Becker, CD ;
Grossholz, M ;
Becker, M ;
Mentha, G ;
dePeyer, R ;
Terrier, F .
RADIOLOGY, 1997, 205 (02) :523-530
[5]   APPROXIMATE BINOMIAL CONFIDENCE-LIMITS [J].
BLYTH, CR .
JOURNAL OF THE AMERICAN STATISTICAL ASSOCIATION, 1986, 81 (395) :843-855
[6]   SIGNAL DETECTABILITY - THE USE OF ROC CURVES AND THEIR ANALYSES [J].
CENTOR, RM .
MEDICAL DECISION MAKING, 1991, 11 (02) :102-106
[7]   Choledocholithiasis: Comparison of MR cholangiography and endoscopic retrograde cholangiography [J].
Chan, YL ;
Chan, ACW ;
Lam, WWM ;
Lee, DWH ;
Chung, SSC ;
Sung, JJY ;
Cheung, HS ;
Li, AKC ;
Metreweli, C .
RADIOLOGY, 1996, 200 (01) :85-89
[8]   HALVING MR IMAGING TIME BY CONJUGATION - DEMONSTRATION AT 3.5 KG [J].
FEINBERG, DA ;
HALE, JD ;
WATTS, JC ;
KAUFMAN, L ;
MARK, A .
RADIOLOGY, 1986, 161 (02) :527-531
[9]   DIAGNOSIS OF CHOLEDOCHOLITHIASIS - VALUE OF MR CHOLANGIOGRAPHY [J].
GUIBAUD, L ;
BRET, PM ;
REINHOLD, C ;
ATRI, M ;
BARKUN, ANG .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1994, 163 (04) :847-850
[10]   BILE-DUCT OBSTRUCTION AND CHOLEDOCHOLITHIASIS - DIAGNOSIS WITH MR CHOLANGIOGRAPHY [J].
GUIBAUD, L ;
BRET, PM ;
REINHOLD, C ;
ATRI, M ;
BARKUN, AN .
RADIOLOGY, 1995, 197 (01) :109-115