Lead ion-selective membrane electrode based on 1,10-dibenzyl-1,10-diaza-18-crown-6

被引:107
作者
Mousavi, MF
Sahari, S
Alizadeh, N
Shamsipur, M
机构
[1] Tarbiat Modarres Univ, Dept Chem, Tehran, Iran
[2] Razi Univ, Dept Chem, Kermanshah, Iran
关键词
lead; ion-selective membrane electrode; crown ether; potentiometry;
D O I
10.1016/S0003-2670(00)00818-7
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A PVC membrane lead(II) ion-selective electrode has been constructed using 1,10-dibenzyl-1,10-diaza-18-crown-6 (DBzDA 18C6) as membrane carrier. The sensor shows a Nernstian response for Pb(II) ions over a wide concentration range (5.0x10(-5) to 1.0x10(-2) M). It has a fast response time and can be used for more than 10 months without any considerable divergence in potentials. The proposed sensor exhibits comparatively good selectivities with respect to alkali, alkaline earth and some transition and heavy metal ions. It was employed as an indicator electrode in potentiometric titration of EDTA with lead ions and used for direct determination of lead in waste water. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:189 / 194
页数:6
相关论文
共 15 条
[1]  
AMMANN D, 1983, ION SEL ELECTRODE R, V5, P3
[2]   LIPOPHILIC SALTS AS MEMBRANE ADDITIVES AND THEIR INFLUENCE ON THE PROPERTIES OF MACROELECTRODES AND MICROELECTRODES BASED ON NEUTRAL CARRIERS [J].
AMMANN, D ;
PRETSCH, E ;
SIMON, W ;
LINDNER, E ;
BEZEGH, A ;
PUNGOR, E .
ANALYTICA CHIMICA ACTA, 1985, 171 (MAY) :119-129
[3]   Carrier-based ion-selective electrodes and bulk optodes. 1. General characteristics [J].
Bakker, E ;
Buhlmann, P ;
Pretsch, E .
CHEMICAL REVIEWS, 1997, 97 (08) :3083-3132
[4]   PVC-based hexathia-18-crown-6-tetraone sensor for mercury(II) ions [J].
Fakhari, AR ;
Ganjali, MR ;
Shamsipur, M .
ANALYTICAL CHEMISTRY, 1997, 69 (18) :3693-3696
[5]   LITHIUM SELECTIVE IONOPHORES BASED ON PENDANT ARM SUBSTITUTED CROWN-ETHERS [J].
FAULKNER, S ;
KATAKY, R ;
PARKER, D ;
TEASDALE, A .
JOURNAL OF THE CHEMICAL SOCIETY-PERKIN TRANSACTIONS 2, 1995, (09) :1761-1769
[6]   MEMBRANE TECHNOLOGY AND DYNAMIC-RESPONSE OF ION-SELECTIVE LIQUID-MEMBRANE ELECTRODES [J].
HUSER, M ;
GEHRIG, PM ;
MORF, WE ;
SIMON, W ;
LINDNER, E ;
JENEY, J ;
TOTH, K ;
PUNGOR, E .
ANALYTICAL CHEMISTRY, 1991, 63 (14) :1380-1386
[7]  
IUPAC, 1979, PURE APPL CHEM, V48, P127, DOI DOI 10.1351/PAC197648010127
[8]   THERMODYNAMIC AND KINETIC DATA FOR MACROCYCLE INTERACTION WITH CATIONS AND ANIONS [J].
IZATT, RM ;
PAWLAK, K ;
BRADSHAW, JS ;
BRUENING, RL .
CHEMICAL REVIEWS, 1991, 91 (08) :1721-2085
[9]   COPPER(II)-SELECTIVE ELECTRODE USING THIURAM DISULFIDE NEUTRAL CARRIERS [J].
KAMATA, S ;
BHALE, A ;
FUKUNAGA, Y ;
MURATA, H .
ANALYTICAL CHEMISTRY, 1988, 60 (22) :2464-2467
[10]  
MOUSAVI MF, IN PRESS SENSOR AC B