Improving ventricular-arterial coupling during resuscitation from shock: Effects on cardiovascular function and systemic perfusion

被引:14
作者
Chang, MC [1 ]
Martin, RS [1 ]
Scherer, LA [1 ]
Meredith, JW [1 ]
机构
[1] Wake Forest Univ, Sch Med, Dept Gen Surg, Winston Salem, NC 27157 USA
来源
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE | 2002年 / 53卷 / 04期
关键词
shock resuscitation; perfusion; hemodynamics; resuscitation end-points; ventricular-arterial coupling; pressure-volume diagram;
D O I
10.1097/00005373-200210000-00010
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background. Efficacy of circulation depends on interactions between the heart and the vascular system. Ventricular-arterial coupling (VAC) has been described as an important determinant of cardiovascular function during resuscitation from shock. However, no prospective studies examining VAC and systemic perfusion have been performed. VAC is measured by the ratio of afterload (aortic input impedance [E-a]) to contractility (end-systolic elastance [E-es]). Lowering E-a/E-es is associated with better VAC and improved myocardial work efficiency. Our hypothesis was that optimizing VAC during resuscitation results in improved myocardial work efficiency while simultaneously improving systemic perfusion. Methods This was a prospective study in a consecutive series of critically injured patients. Hemodynamic variables, including E-a, E-es, and myocardial work efficiency were evaluated by constructing ventricular pressure-volume loops at the bedside during resuscitation. After pulmonary artery catheterization and adequate fluid resuscitation, left ventricular power output and E-a/E-es were optimized with inotropic agents and/or afterload reduction. Efficiency was calculated as stroke work/total left ventricular energy expenditure. Tissue perfusion was estimated by calculating base deficit clearance per hour. Results. Twenty-three patients were studied over a 9-month period. Fifteen patients required inotropic support or afterload reduction. Improvements were seen in E-a/E-es (from 1.0 +/- 0.4 to 0.6 +/- 0.2 mm Hg/mL/m(2), P = 0.0004), and left ventricular power output (from 280 +/- 77 to 350 +/- 81 L/min/m(2 .) mm Hg, P = 0.003) with resuscitation. A concomitant improvement in myocardial efficiency (from 70% +/- 8.0% to 77% +/- 5.0%, p = 0.0001) and base deficit clearance (from 0.1 +/- 0.4 to -0.2 +/- 0.1 mEq/L/h, p = 0.006) was seen. Conclusion. Improved ventricular-arterial coupling during resuscitation is associated with improved myocardial efficiency and systemic tissue perfusion. Perfusion can be improved at lower energy cost to the heart by focusing on thermodynamic principles during resuscitation.
引用
收藏
页码:679 / 685
页数:7
相关论文
共 21 条
[1]   VENTRICULOARTERIAL COUPLING IN NORMAL AND FAILING HEART IN HUMANS [J].
ASANOI, H ;
SASAYAMA, S ;
KAMEYAMA, T .
CIRCULATION RESEARCH, 1989, 65 (02) :483-493
[2]  
Chang MC, 1996, ARCH SURG-CHICAGO, V131, P728
[3]   Cardiac preload, splanchnic perfusion, and their relationship during resuscitation in trauma patients [J].
Chang, MC ;
Meredith, JW .
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 1997, 42 (04) :577-584
[4]  
Chang MC, 1997, SHOCK, V7, P413, DOI 10.1097/00024382-199706000-00003
[5]  
Chang MC, 1999, NEW HORIZ-SCI PRACT, V7, P35
[6]  
Chang MC, 2000, J TRAUMA, V49, P26, DOI 10.1097/00005373-200007000-00004
[7]   Redefining cardiovascular performance during resuscitation: Ventricular stroke work, power, and the pressure-volume diagram [J].
Chang, MC ;
Mondy, JS ;
Meredith, JW ;
Holcroft, JW .
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 1998, 45 (03) :470-478
[8]  
CIVETTA JM, 1992, CRITICAL CARE
[9]  
HOLCROFT JW, 1988, CARE SURG PATIENTS P, P1
[10]   Elevated arterial base deficit in trauma patients: A marker of impaired oxygen utilization [J].
Kincaid, EH ;
Miller, PR ;
Meredith, JW ;
Rahman, N ;
Chang, MC .
JOURNAL OF THE AMERICAN COLLEGE OF SURGEONS, 1998, 187 (04) :384-392