Reliability and precision of isokinetic strength and muscular endurance for the quadriceps and hamstrings

被引:158
作者
Pincivero, DM
Lephart, SM
Karunakara, RA
机构
[1] Neuromuscular Research Laboratory, University of Pittsburg, Pittsburg, PA
[2] 127 Trees Hall, University of Pittsburgh, Pittsburgh
关键词
isokinetic; reliability; endurance; precision; quadriceps; hamstrings;
D O I
10.1055/s-2007-972605
中图分类号
G8 [体育];
学科分类号
04 [教育学]; 0403 [体育学];
摘要
The importance of accurately reproducing isokinetic strength values is critical for the assessment of training induced changes in muscle function. The purpose of this study was to determine the test re-test reliability of the Biodex System 2 Isokinetic Dynamometer for concentric quadricep and hamstring strength and muscular endurance. Twenty-one healthy volunteers underwent isokinetic testing on 2 occasions separated by 7 days. Each subject performed 5 repetitions at 60 degrees/second followed by a muscular endurance test which consisted of 30 repetitions at 180 degrees/second. The results demonstrated high ICC values ranging from r = 0.88 to r = 0.97 and r = 0.82 to r = 0.96 for variables measured at 60 degrees/second and 180 degrees/second, respectively. SEM values were found to range from low to moderate, 4.8% to 11.6% and 5.6% to 10.8%, at 60 and 180 degrees/second, respectively. ICC coefficients were found to be low, r = 0.52 to r = 0.74, and SEM values were found to be high, 9.8% to 20.8%, for the work fatigue index at 180 degrees/second. The results demonstrate that isokinetic values obtained at 60 and 180 degrees/second are highly reproducible with the Biodex System 2 Dynamometer provided that adequate calibration, gravity correction and patient positioning is recorded and standardized. However, the work fatigue index as a measure of muscular endurance has not been shown to be reliable or precise. Changes in muscular strength over time should be considered valid if these differences lie beyond the SEM values reported in this study.
引用
收藏
页码:113 / 117
页数:5
相关论文
共 16 条
[1]
*BIOD MED INC, 1994, BIOD SYST 2 IS DYN A
[2]
BURDETT R G, 1987, Journal of Orthopaedic and Sports Physical Therapy, V8, P484
[3]
CURRIER DP, 1984, ELEMENTS RES PHYSICA
[4]
Denegar CR, 1993, J SPORT REHABIL, V2, P35, DOI DOI 10.1123/JSR.2.1.35
[5]
FEIRING D C, 1990, Journal of Orthopaedic and Sports Physical Therapy, V11, P298
[6]
GROSS M T, 1991, Journal of Orthopaedic and Sports Physical Therapy, V13, P329
[7]
HALD R D, 1987, Journal of Orthopaedic and Sports Physical Therapy, V9, P86
[8]
Hislop H J, 1967, Phys Ther, V47, P114
[9]
*LUM INC, 1975, CYB 2 TEST PROT
[10]
MCARDLE WD, 1991, EXERCISE PHYSL ENERG, P124