Physiological relevance of uniform elastic tube-models to infer descending aortic wave reflection: A problem of identifiability

被引:9
作者
Burattini, R
Campbell, KB
机构
[1] Univ Ancona, Dipartimento Elettron & Automat, I-60131 Ancona, Italy
[2] Washington State Univ, Dept Vet & Comparat Anat Pharmacol & Physiol, Pullman, WA 99164 USA
关键词
arterial pulse wave propagation; determinacy problem; arterial effective reflection site; vascular impedance;
D O I
10.1114/1.291
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A uniform, frictional elastic tube terminating in a pure resistor (model A), was compared with a uniform, frictionless elastic tube, terminating in a first-order low-pass filter load (model B). The aim was to address an identifiability problem in uniqueness of parameter estimates and to evaluate the physiological meaning of tube-length estimates obtained from these models applied to the descending aortic circulation. Measurements of high descending aortic pressure and flow were taken from three anaesthetized, open-chest dogs and used to estimate the model parameters. A simultaneous measurement of terminal aortic pressure was used to estimate the foot-to-foot pulse wave velocity. A flow-fitting procedure yielded a multiplicity of equivalent solutions for the wave transit time across the transmission tubes (tau(ai), for model A and tau(bi) for model B, i=0,1,2,...,N,...) and the related tube-lengths d(ai) and d(bi), respectively. The tube length represents the distance to an effective reflection site (effective length) of the descending aortic circulation. Assuming that this length should be no longer than the dimensions of the body, the lowest estimates (i=0) of wave transit time and tube length (average +/-SE: tau(ao)=85.7 +/-10.8 ms and d(ao)=53.4+/-3.7cm for model A; tau(bo)=46.6+/-6.7 ms and d(bo)=29.1+/-3.5 cm for model B) were identifiable as unique and acceptable solutions. Model A located the effective reflection site a few centimeters below the terminal aortic region. This location is inconsistent with the use of a pure resistor as a tube's terminal load. Further, relatively high estimates of longitudinal frictional losses violated the assumption of small losses across the transmission path and yielded an unphysiological mean-pressure drop of 7.1+/-2.3 mm Hg. The estimates of db, provided by model B located the effective reflection site near the origin of the renal arteries. The model-predicted pressure wave at this location approximated the measured pressure. Thus, model B represents a significant improve ment over model A as a tool to infer wave travel and reflection in the descending aortic circulation. (C) 2000 Biomedical Engineering Society. [S0090-6964(00)00505-1].
引用
收藏
页码:512 / 523
页数:12
相关论文
共 31 条
[1]  
[Anonymous], 1968, GRUNDLAGEN DYNAMIK A
[2]  
Bard Y., 1974, Nonlinear Parameter Estimation
[3]  
BELLMAN R, 1970, Mathematical Biosciences, V7, P329, DOI 10.1016/0025-5564(70)90132-X
[4]   REPEATED REFLECTION OF WAVES IN THE SYSTEMIC ARTERIAL SYSTEM [J].
BERGER, DS ;
LI, JKJ ;
LASKEY, WK ;
NOORDERGRAAF, A .
AMERICAN JOURNAL OF PHYSIOLOGY, 1993, 264 (01) :H269-H281
[5]   PROBLEMS OF DETERMINACY IN COMPARTMENTAL MODELING WITH APPLICATION TO BILIRUBIN KINETICS [J].
BROWN, RF ;
GODFREY, KR .
MATHEMATICAL BIOSCIENCES, 1978, 40 (3-4) :205-224
[6]   2 ARTERIAL EFFECTIVE REFLECTING SITES MAY APPEAR AS ONE TO THE HEART [J].
BURATTINI, R ;
KNOWLEN, GG ;
CAMPBELL, KB .
CIRCULATION RESEARCH, 1991, 68 (01) :85-99
[7]   LUMPED MODEL OF TERMINAL AORTIC IMPEDANCE IN THE DOG [J].
BURATTINI, R ;
FOGLIARDI, R ;
CAMPBELL, KB .
ANNALS OF BIOMEDICAL ENGINEERING, 1994, 22 (04) :381-391
[8]   A SIMPLE ALGORITHM FOR DEFINING THE MEAN CARDIAC CYCLE OF AORTIC FLOW AND PRESSURE DURING STEADY-STATE [J].
BURATTINI, R ;
FIORETTI, S ;
JETTO, L .
COMPUTERS AND BIOMEDICAL RESEARCH, 1985, 18 (04) :303-312
[9]   EFFECTIVE LENGTH OF THE ARTERIAL CIRCULATION DETERMINED IN THE DOG BY AID OF A MODEL OF THE SYSTEMIC INPUT IMPEDANCE [J].
BURATTINI, R ;
DICARLO, S .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1988, 35 (01) :53-61
[10]   EFFECTIVE DISTRIBUTED COMPLIANCE OF THE CANINE DESCENDING AORTA ESTIMATED BY MODIFIED T-TUBE MODEL [J].
BURATTINI, R ;
CAMPBELL, KB .
AMERICAN JOURNAL OF PHYSIOLOGY, 1993, 264 (06) :H1977-H1987