Peptide Separations by On-Line MudPIT Compared to Isoelectric Focusing in an Off-Gel Format: Application to a Membrane-Enriched Fraction from C2C12 Mouse Skeletal Muscle Cells

被引:50
作者
Elschenbroich, Sarah [1 ,2 ]
Ignatchenko, Vladimir [1 ]
Sharma, Parveen [3 ,4 ]
Schmitt-Ulms, Gerold [5 ]
Gramolini, Anthony O. [4 ]
Kislinger, Thomas [1 ,6 ]
机构
[1] Univ Hlth Network, Ontario Canc Inst, Toronto, ON, Canada
[2] Univ Erlangen Nurnberg, Dept Chem & Pharm, D-8520 Erlangen, Germany
[3] Univ Toronto, Banting & Best Dept Med Res, Toronto, ON M5S 1A1, Canada
[4] Univ Toronto, Dept Physiol, Toronto, ON M5S 1A1, Canada
[5] Univ Toronto, Dept Lab Med & Pathol, Toronto, ON M5S 1A1, Canada
[6] Univ Toronto, Dept Med Biophys, Toronto, ON M5S 1A1, Canada
基金
加拿大健康研究院;
关键词
Proteomics; OFFGEL; MudPIT; membrane; C2C12; cells; STRONG-CATION-EXCHANGE; EMBRYONIC STEM-CELLS; MULTIDIMENSIONAL LIQUID-CHROMATOGRAPHY; PROTEIN IDENTIFICATION TECHNOLOGY; MASS-SPECTROMETRY; SHOTGUN PROTEOMICS; PLASMA-MEMBRANE; CARCINOMA-CELLS; IN-VIVO; TANDEM;
D O I
10.1021/pr900318k
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
High-resolution peptide separation is pivotal for successful shotgun proteomics. The need for capable techniques propels invention and improvement of ever more sophisticated approaches. Recently, Agilent Technologies has introduced the OFFGEL fractionator, which conducts peptide separation by isoelectric focusing in an off-gel setup. This platform has been shown to accomplish high resolution of peptides for diverse sample types, yielding valuable advantages over comparable separation techniques. In this study, we deliver the first comparison of the newly emerging OFFGEL approach to the well-established on-line MudPIT platform. Samples from a membrane-enriched fraction isolated from murine C2C12 cells were subjected to replicate analysis by OFFGEL (12 fractions, pH 3-10) followed by RP-LC-MS/MS or 12-step on-line MudPIT. OFFGEL analyses yielded 1398 proteins (identified by 10 269 peptides), while 1428 proteins (11 078 peptides) were detected with the MudPIT approach. Thus, our data shows that both platforms produce highly comparable results in terms of protein/peptide identifications and reproducibility for the sample type analyzed. We achieve more accurate peptide focusing after OFFGEL fractionation with 88% of all peptides binned to a single fraction, as compared to 61% of peptides detected in only one step in MudPIT analyses. Our study suggests that both platforms are equally capable of high quality peptide separation of a sample with medium complexity, rendering them comparably valuable for comprehensive proteomic analyses.
引用
收藏
页码:4860 / 4869
页数:10
相关论文
共 55 条
[1]   Quantitative mass spectrometric multiple reaction monitoring assays for major plasma proteins [J].
Anderson, L ;
Hunter, CL .
MOLECULAR & CELLULAR PROTEOMICS, 2006, 5 (04) :573-588
[2]   Limitations of the Colloidal Silica Method in Mapping the Endothelial Plasma Membrane Proteome of the Mouse Heart [J].
Arjunan, Selvam ;
Reinartz, Michael ;
Emde, Barbara ;
Zanger, Klaus ;
Schrader, Juergen .
CELL BIOCHEMISTRY AND BIOPHYSICS, 2009, 53 (03) :135-143
[3]   Evaluation of confidence and reproducibility in quantitative proteomics performed by a capillary isoelectric focusing-based proteomic platform coupled with a spectral counting approach [J].
Balgley, Brian M. ;
Wang, Weijie ;
Song, Tao ;
Fang, Xueping ;
Yang, Li ;
Lee, Cheng S. .
ELECTROPHORESIS, 2008, 29 (14) :3047-3054
[4]   Interaction network containing conserved and essential protein complexes in Escherichia coli [J].
Butland, G ;
Peregrín-Alvarez, JM ;
Li, J ;
Yang, WH ;
Yang, XC ;
Canadien, V ;
Starostine, A ;
Richards, D ;
Beattie, B ;
Krogan, N ;
Davey, M ;
Parkinson, J ;
Greenblatt, J ;
Emili, A .
NATURE, 2005, 433 (7025) :531-537
[5]   Gel based isoelectric focusing of peptides and the utility of isoelectric point in protein identification [J].
Cargile, BJ ;
Bundy, JL ;
Freeman, TW ;
Stephenson, JL .
JOURNAL OF PROTEOME RESEARCH, 2004, 3 (01) :112-119
[6]   Peptides OFFGEL electrophoresis: a suitable pre-analytical step for complex eukaryotic samples fractionation compatible with quantitative iTRAQ labeling [J].
Chenau, Jerome ;
Michelland, Sylvie ;
Sidibe, Jonathan ;
Seve, Michel .
PROTEOME SCIENCE, 2008, 6 (1)
[7]   Integrated proteomic and transcriptomic profiling of mouse lung development and Nmyc target genes [J].
Cox, Brian ;
Kislinger, Thomas ;
Wigle, Dennis A. ;
Kannan, Anitha ;
Brown, Kevin ;
Okubo, Tadashi ;
Hogan, Brigid ;
Jurisica, Igor ;
Frey, Brendan ;
Rossant, Janet ;
Emili, Andrew .
MOLECULAR SYSTEMS BIOLOGY, 2007, 3 (1)
[8]   Comparative systems biology of human and mouse as a tool to guide the modeling of human placental pathology [J].
Cox, Brian ;
Kotlyar, Max ;
Evangelou, Andreas I. ;
Ignatchenko, Vladimir ;
Ignatchenko, Alex ;
Whiteley, Kathie ;
Jurisica, Igor ;
Adamson, S. Lee ;
Rossant, Janet ;
Kislinger, Thomas .
MOLECULAR SYSTEMS BIOLOGY, 2009, 5
[9]   TANDEM: matching proteins with tandem mass spectra [J].
Craig, R ;
Beavis, RC .
BIOINFORMATICS, 2004, 20 (09) :1466-1467
[10]   The biological impact of mass-spectrometry-based proteomics [J].
Cravatt, Benjamin F. ;
Simon, Gabriel M. ;
Yates, John R., III .
NATURE, 2007, 450 (7172) :991-1000