Cavity ringdown heterodyne spectroscopy: High sensitivity with microwatt light power

被引:46
作者
Ye, J [1 ]
Hall, JL
机构
[1] Natl Inst Stand & Technol, Joint Inst Lab Astrophys, Boulder, CO 80309 USA
[2] Univ Colorado, Boulder, CO 80309 USA
来源
PHYSICAL REVIEW A | 2000年 / 61卷 / 06期
关键词
D O I
10.1103/PhysRevA.61.061802
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We present an ac heterodyne technique in cavity ringdown spectroscopy that permits 1 X 10(-10) absorption sensitivity with microwatt-level light power. Two cavity modes, one probing the empty cavity and the other probing intracavity absorption, are excited simultaneously but with their intensities temporally out of phase, with one mode decaying and the other rising. Heterodyne detection between the two modes reveals the dynamic time constants associated with the empty cavity and the additional intracavity gas absorption. The method offers a quick comparison between the on- and off-resonance information, a prerequisite to reaching the fundamental shot-noise limit. This simple and yet important improvement of cavity ringdown spectroscopy should lead to the enhanced performance of a wide range of applications.
引用
收藏
页数:4
相关论文
共 9 条
[1]   MIRROR REFLECTOMETER BASED ON OPTICAL CAVITY DECAY TIME [J].
ANDERSON, DZ ;
FRISCH, JC ;
MASSER, CS .
APPLIED OPTICS, 1984, 23 (08) :1238-1245
[2]   HE-NE LASERS STABILIZED BY SATURATED ABSORPTION IN IODINE AT 612-NM [J].
CEREZ, P ;
BRILLET, A ;
MANPICHOT, CN ;
FELDER, R .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1980, 29 (04) :352-354
[3]   LASER PHASE AND FREQUENCY STABILIZATION USING AN OPTICAL-RESONATOR [J].
DREVER, RWP ;
HALL, JL ;
KOWALSKI, FV ;
HOUGH, J ;
FORD, GM ;
MUNLEY, AJ ;
WARD, H .
APPLIED PHYSICS B-PHOTOPHYSICS AND LASER CHEMISTRY, 1983, 31 (02) :97-105
[4]   ATOMES A IINTERIEUR DUN INTERFEROMETRE PEROT-FABRY [J].
KASTLER, A .
APPLIED OPTICS, 1962, 1 (01) :17-24
[5]   Optical heterodyne detection in cavity ring-down spectroscopy [J].
Levenson, MD ;
Paldus, BA ;
Spence, TG ;
Harb, CC ;
Harris, JS ;
Zare, RN .
CHEMICAL PHYSICS LETTERS, 1998, 290 (4-6) :335-340
[6]   OPTICAL HETERODYNE SPECTROSCOPY ENHANCED BY AN EXTERNAL OPTICAL CAVITY - TOWARD IMPROVED WORKING STANDARDS [J].
MA, LS ;
HALL, JL .
IEEE JOURNAL OF QUANTUM ELECTRONICS, 1990, 26 (11) :2006-2012
[7]   CAVITY RING-DOWN OPTICAL SPECTROMETER FOR ABSORPTION-MEASUREMENTS USING PULSED LASER SOURCES [J].
OKEEFE, A ;
DEACON, DAG .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1988, 59 (12) :2544-2551
[8]   Ultrasensitive surface spectroscopy with a miniature optical resonator [J].
Pipino, ACR .
PHYSICAL REVIEW LETTERS, 1999, 83 (15) :3093-3096
[9]  
YE J, IN PRESS J OPT SOC B