Bridge to transplantation with the DeBakey VAD® axial pump:: a single center report

被引:17
作者
Grinda, JM [1 ]
Latremouille, CH [1 ]
Chevalier, P [1 ]
D'Attelis, N [1 ]
Boughenou, F [1 ]
Guillemain, R [1 ]
Deloche, A [1 ]
Fabiani, JN [1 ]
机构
[1] Hop Europeen Georges Pompidou, Dept Cardiac Surg, F-75015 Paris, France
关键词
transplantation; mechanical assist device; heart failure; non-pulsatile flow;
D O I
10.1016/S1010-7940(02)00612-7
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims: To report our experience with a left ventricular assist device axial pump as a bridge to transplantation: the DeBakey Ventricular Assist Device (VAD). Methods: From February 1999 to February 2002, nine patients (among which eight males), with a mean age of 47 years, all in NYHA functional class IV, were proposed for a bridge to transplantation with the DeBakey VAD. Five patients had primary dilated cardiomyopathy, four had ischemic cardiomyopathy. All the patients had inotropic support prior to the intervention (dobutamine with a mean dose of 12 mcg/kg per min), six had an intra-aortic counterpulsation, four presented ventricular rhythm disorders. Interventions were performed through sternotomy alone (no need for an abdominal pocket) under extra-corporeal circulation on beating heart (except in one patient suffering from an apical thrombosis for which cardioplegic arrest was performed) as followed: implantation of the apical inflow cannula, tunneling of the percutaneous cable, implantation of the outflow graft under aortic side clamping, starting of the DeBakey VAD during CPB weaning-off. Results: Mean support duration was 81 +/- 62 days (16-224 days). Eight reoperations were required (three for bleeding or cardiac tamponade, one for haemoperitoneum, one for aortic bifurcation thrombectomy, one for right ventricular assist device implantation, two for iterative replacements of the DeBakey VAD). A significant hemolysis was observed in two patients. No device infection or dysfunction were observed. Secondary recovery of a pulsed flow was observed either clinically or by Echo-Doppler in six patients. Five patients were transplanted, four died prior to transplantation (three from multi-organ failure on post-operative day 35, 16 and 50, respectively, and the last patient was found disconnected at day 109). Conclusions: The DeBakey VAD is at the origin of renewed interest for continuous flow assist devices. Still under evaluation, the advantages of miniaturization and facility of implantation of this new device seem to be promising. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:965 / 970
页数:6
相关论文
共 19 条
[1]   AXIAL-FLOW VENTRICULAR ASSIST DEVICE - SYSTEM PERFORMANCE CONSIDERATIONS [J].
DAMM, G ;
MIZUGUCHI, K ;
ABER, G ;
BACAK, J ;
AKKERMAN, J ;
BOZEMAN, R ;
SVEJKOVSKY, P ;
TAKATANI, S ;
NOSE, Y ;
NOON, GP ;
DEBAKEY, ME .
ARTIFICIAL ORGANS, 1994, 18 (01) :44-48
[2]  
DeBakey ME, 1997, ARTIF ORGANS, V21, P1149
[3]   Implantable left ventricular assist devices provide an excellent outpatient bridge to transplantation and recovery [J].
DeRose, JJ ;
Umana, JP ;
Argenziano, M ;
Catanese, KA ;
Gardocki, MT ;
Flannery, M ;
Levin, HR ;
Sun, BC ;
Rose, EA ;
Oz, MC .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1997, 30 (07) :1773-1777
[4]   Device and patient management in a bridge-to-transplant setting [J].
El-Banayosy, A ;
Körfer, R ;
Arusoglu, L ;
Kizner, L ;
Morshuis, M ;
Milting, H ;
Tenderich, G ;
Fey, O ;
Minami, K .
ANNALS OF THORACIC SURGERY, 2001, 71 (03) :S98-S102
[5]   Ex vivo evaluation of the NASA/DeBakey axial flow ventricular assist device - Results of a 2 week screening test [J].
Kawahito, K ;
Benkowski, R ;
Otsubo, S ;
Rosenbaum, B ;
Moreland, R ;
Noon, GP ;
Nose, Y ;
DeBakey, ME .
ASAIO JOURNAL, 1996, 42 (05) :M754-M757
[6]  
LeBesnerais P, 1996, ARCH MAL COEUR VAISS, V89, P71
[7]  
Loisance D, 1996, ARCH MAL COEUR VAISS, V89, P65
[8]   One hundred patients with the HeartMate left ventricular assist device: Evolving concepts and technology [J].
McCarthy, PM ;
Smedira, NO ;
Vargo, RL ;
Goormastic, M ;
Hobbs, RE ;
Starling, RC ;
Young, JB .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1998, 115 (04) :904-912
[9]   DEVELOPMENT OF THE BAYLOR NASA AXIAL-FLOW VENTRICULAR ASSIST DEVICE - IN-VITRO PERFORMANCE AND SYSTEMATIC HEMOLYSIS TEST-RESULTS [J].
MIZUGUCHI, K ;
DAMM, GA ;
BOZEMAN, RJ ;
AKKERMAN, JW ;
ABER, GS ;
SVEJKOVSKY, PA ;
BACAK, JW ;
ORIME, Y ;
TAKATANI, S ;
NOSE, Y ;
NOON, GP ;
DEBAKEY, ME .
ARTIFICIAL ORGANS, 1994, 18 (01) :32-43
[10]  
MORLEY D, 1998, ASAIO J, V44, P30