Ion chromatographic analysis of cyanate in gold processing samples containing large concentrations of copper(I) and other metallo-cyanide complexes

被引:8
作者
Fagan, P
Paull, B
Haddad, PR
Dunne, R
Kamar, H
机构
[1] UNIV TASMANIA,DEPT CHEM,HOBART,TAS 7001,AUSTRALIA
[2] NEWCREST MINING LTD,PERTH,WA 6892,AUSTRALIA
[3] LAKFIELD RES,LAKEFIELD,ON K0L 2H0,CANADA
关键词
cyanate; metal-cyanide complexes; copper(I)-cyanide;
D O I
10.1016/S0021-9673(96)01027-8
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
An ion chromatographic (IC) method was developed for the determination of cyanate in gold cyanidation samples containing large concentrations of metallo-cyanide complexes, The analysis was performed on a Waters HC IC-Pak A anion-exchange column with an anthranilic acid eluent, with detection achieved using indirect UV at 355 nm. Two procedures were developed for removal of the metallo-cyanide complexes prior to the IC analysis. The first was a manual off-line method which used solid-phase extraction cartridges containing a strong anion-exchange resin to trap the complexes and to then enable determination of cyanate without interference. In the second approach, an automated on-line method was developed which used an anion-exchange guard column to trap the complexes and a column switching valve to allow backflushing of the cyanate from the guard column. This enabled the total analysis to be performed in a time of 10-14 min, depending on the sample composition. Finally, a comparison of results obtained by the standard Kjeldahl nitrogen method for cyanate and the IC method revealed an interference in the Kjeldahl method for samples containing large concentrations of Cu(I)-cyanide complexes.
引用
收藏
页码:175 / 183
页数:9
相关论文
共 24 条
[1]  
American Public Health Association, 1992, STAND METH EX WAT WA, P4
[2]   ADSORPTION OF GOLD FROM CYANIDE SOLUTIONS BY ANIONIC RESINS [J].
AVESTON, J ;
EVEREST, DA ;
WELLS, RA .
JOURNAL OF THE CHEMICAL SOCIETY, 1958, (JAN) :231-239
[3]   ULTRA-VIOLET VISUALIZATION OF INORGANIC ANIONS BY REVERSED-PHASE ION-INTERACTION CHROMATOGRAPHY - FACTORS THAT CONTROL RETENTION AND SELECTIVITY [J].
BARBER, WE ;
CARR, PW .
JOURNAL OF CHROMATOGRAPHY, 1984, 301 (01) :25-38
[4]   PERMANENTLY COATED ION-EXCHANGERS FOR LIQUID-CHROMATOGRAPHIC DETERMINATION OF ANIONIC SPECIES IN SAMPLES FROM ENVIRONMENTAL-CONTROL PROCESSES [J].
BARKLEY, DJ ;
DAHMS, TE ;
VILLENEUVE, KN .
JOURNAL OF CHROMATOGRAPHY, 1987, 395 :631-640
[5]   CHROMATOGRAPHY OF RADIOLABELED ANIONS USING REVERSED-PHASE LIQUID-CHROMATOGRAPHIC COLUMNS [J].
BOOTHE, TE ;
EMRAN, AM ;
FINN, RD ;
KOTHARI, PJ ;
VORA, MM .
JOURNAL OF CHROMATOGRAPHY, 1985, 333 (01) :269-275
[6]   ION EXCHANGE PROCESS FOR RECOVERY OF GOLD FROM CYANIDE SOLUTION [J].
BURSTALL, FH ;
FORREST, PJ ;
KEMBER, NF ;
WELLS, RA .
INDUSTRIAL AND ENGINEERING CHEMISTRY, 1953, 45 (08) :1648-1658
[7]  
COTTON FA, 1987, BASIC INORGANIC CHEM, P327
[8]   DETERMINATION OF FREE CYANIDE IN GOLD CYANIDATION PROCESS LIQUORS BY ION-INTERACTION CHROMATOGRAPHY WITH POSTCOLUMN DERIVATIZATION [J].
FAGAN, PA ;
HADDAD, PR .
JOURNAL OF CHROMATOGRAPHY, 1991, 550 (1-2) :559-571
[9]   SEPARATION OF METAL-CYANIDE COMPLEXES BY REVERSED-PHASE ION-INTERACTION HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
GIROUX, L ;
BARKLEY, DJ .
CANADIAN JOURNAL OF CHEMISTRY-REVUE CANADIENNE DE CHIMIE, 1994, 72 (02) :269-273
[10]  
HADD PR, 1990, ION CHROMATOGRAPHY P, P354