Multilayer conformal applicator for microwave heating and brachytherapy treatment of superficial tissue disease

被引:30
作者
Juang, T.
Stauffer, P. R.
Neuman, D. G.
Schlorff, J. L.
机构
[1] Duke Univ, Med Ctr, Dept Radiat Oncol, Durham, NC 27710 USA
[2] Bionix Dev Corp, Paoli, PA USA
关键词
brachytherapy; breast cancer; hyperthermia; radiation therapy; waterbolus;
D O I
10.1080/02656730600931815
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: The purpose of this study was to construct and perform preliminary functionality evaluations of a multilayer conformal applicator with provisions for thermal monitoring, tight conformity and simultaneous microwave heating and brachytherapy treatment of large-area contoured surfaces. Materials and methods: The multilayer conformal applicator consists of thermal monitoring catheters for fibre-optic monitoring of skin temperatures, a waterbolus, a PCB microwave antenna array, a dielectric spacer for brachytherapy considerations, brachytherapy catheters for delivering HDR radiation and an inflatable air bladder for improving conformity to contoured surfaces. The applicator also includes an elastic attachment structure to hold the applicator securely in place on the patient. The conformity of the applicator to irregular surfaces was evaluated through CT imaging of the applicator fitted onto a life-sized human torso phantom. The fluid flow dynamics of the waterbolus, which impact the effectiveness of temperature control, were evaluated with thermometry during a 19 degrees C step change temperature of the circulating water. Results: CT imaging showed improved conformity to the torso phantom surface following the application of gentle inward pressure from inflating the outer air bladder. Only a small number of 1-5mm sized air gaps separated the conformal applicator and tissue surface. Thermometry testing of the bolus fluid flow dynamics demonstrated temperature uniformity within +/- 0.82 degrees C across a 19 x 34 x 0.6 cm area bolus and +/- 0.85 degrees C across a large 42 x 32 x 0.6 cm area bolus. Conclusion: CT scans of the applicator confirmed that the applicator conforms well to complex body contours and should maintain good conformity and positional stability even when worn on a mobile patient. Thermometry testing of two different waterbolus geometries demonstrated that uniform circulation and temperature control can be maintained throughout large, complex bolus shapes.
引用
收藏
页码:527 / 544
页数:18
相关论文
共 44 条
[1]   FDTD SIMULATIONS OF CLINI-THERM APPLICATORS ON INHOMOGENEOUS PLANAR TISSUE MODELS [J].
CHAN, KW ;
MCDOUGALL, JA ;
CHOU, CK .
INTERNATIONAL JOURNAL OF HYPERTHERMIA, 1995, 11 (06) :809-820
[2]   EVALUATION OF CAPTIVE BOLUS APPLICATORS [J].
CHOU, CK ;
MCDOUGALL, JA ;
CHAN, KW ;
LUK, KH .
MEDICAL PHYSICS, 1990, 17 (04) :705-709
[3]   Effects of waterbolus size, shape and configuration on the SAR distribution pattern of the Lucite cone applicator [J].
de Bruijne, M ;
Samaras, T ;
Bakker, JF ;
Van Rhoon, GC .
INTERNATIONAL JOURNAL OF HYPERTHERMIA, 2006, 22 (01) :15-28
[4]   ARRHENIUS RELATIONSHIPS FROM THE MOLECULE AND CELL TO THE CLINIC [J].
DEWEY, WC .
INTERNATIONAL JOURNAL OF HYPERTHERMIA, 1994, 10 (04) :457-483
[5]   Contact flexible microstrip applicators (CFMA) in a range from microwaves up to short waves [J].
Gelvich, EA ;
Mazokhin, VN .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2002, 49 (09) :1015-1023
[6]   Dual-mode antenna design for microwave heating and noninvasive thermometry of superficial tissue disease [J].
Jacobsen, S ;
Stauffer, PR ;
Neuman, DG .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2000, 47 (11) :1500-1509
[7]   Improved spatial resolution in thermography obtained by a two-layered structure of microstrip spirals [J].
Jacobsen, S ;
Stauffer, PR .
JOURNAL OF ELECTROMAGNETIC WAVES AND APPLICATIONS, 1999, 13 (03) :307-323
[8]   Characterization of a tranceiving antenna concept for microwave heating and thermometry of superficial tumors - Abstract [J].
Jacobsen, S ;
Murberg, A ;
Stauffer, PR .
JOURNAL OF ELECTROMAGNETIC WAVES AND APPLICATIONS, 1998, 12 (03) :351-352
[9]   Randomized trial of hyperthermia and radiation for superficial tumors [J].
Jones, EL ;
Oleson, JR ;
Prosnitz, LR ;
Samulski, TV ;
Vujaskovic, Z ;
Yu, DH ;
Sanders, LL ;
Dewhirst, MW .
JOURNAL OF CLINICAL ONCOLOGY, 2005, 23 (13) :3079-3085
[10]  
JUANG T, 2004, INT C IEEE ENG MED B