Evaluation of the marginal fit of three margin designs of resin composite crowns using CAD/CAM

被引:123
作者
Tsitrou, Effrosyni A. [1 ]
Northeast, Simon E. [1 ]
van Noort, Richard [1 ]
机构
[1] Univ Sheffield, Sch Clin Dent, Dept Adult Dent Care, Sheffield S10 2TA, S Yorkshire, England
关键词
resin composite; resin composite crowns; dental materials; CAD/CAM; CEREC; marginal gap; replica technique;
D O I
10.1016/j.jdent.2006.04.008
中图分类号
R78 [口腔科学];
学科分类号
1003 [口腔医学];
摘要
Objectives: To examine the marginal fit of resin composite crowns manufactured with the CEREC 3 system employing three different margin designs; bevel, chamfer and shoulder, by means of a replica technique and a luting agent. Methods: Three master casts were fabricated from an impression of a typodont molar tooth and a full-coverage crown prepared with a marginal finish of a bevel, a chamfer and a shoulder. Each cast was replicated 10 times (n = 10). Scanning of the replicas and crown designing was performed using the CEREC Scan(TM) system. The crowns were milled from Paradigm MZ100(TM) composite resin blocks. The marginal fit of the crowns was evaluated with a replica technique (AquaSil(TM) LV, Dentsply), and with a resin composite cement (RelyX(TM) Unicem, Aplicap(TM)) and measured with a travelling microscope. Statistical analysis was performed using two-way ANOVA. Results: For the replica technique the average marginal gaps recorded were: Bevel Group 105 +/- 34 mu m, Chamfer Group 94 +/- 27 mu m and Shoulder Group 91 +/- 22 mu m. For the resin composite cement the average marginal gaps were: Bevel Group 102 +/- 28 mu m, Chamfer Group 91 +/- 11 mu m and Shoulder Group 77 +/- 8 mu m. Two-way ANOVA analysis showed that there was no statistically significant difference between the three groups of finishing lines regardless of the cementation technique used. Conclusions: The marginal gap of resin composite crowns manufactured with the CEREC 3 system is within the range of clinical acceptance, regardless of the finishing line prepared or the cementation technique used. (C) 2006 Elsevier Ltd. All rights reserved.
引用
收藏
页码:68 / 73
页数:6
相关论文
共 33 条
[1]
ASCHHEIM KW, 2001, ESTHETIC DENT CLIN A
[2]
Bayne SC, 1996, QUINTESSENCE INT, V27, P431
[3]
Evaluation of the marginal accuracy of different all-ceramic crown systems after simulation in the artificial mouth [J].
Beschnidt, SM ;
Strub, JR .
JOURNAL OF ORAL REHABILITATION, 1999, 26 (07) :582-593
[4]
Bindl A, 1999, Int J Comput Dent, V2, P97
[5]
CLINICAL AND RESEARCH ADVANCEMENTS IN CAST-GOLD RESTORATIONS [J].
CHRISTENSEN, GJ .
JOURNAL OF PROSTHETIC DENTISTRY, 1971, 25 (01) :62-+
[6]
Marginal fit and short-term clinical performance of porcelain-veneered CICERO, CEREC, and Procera onlays [J].
Denissen, H ;
Dozic, A ;
van der Zel, J ;
van Waas, M .
JOURNAL OF PROSTHETIC DENTISTRY, 2000, 84 (05) :506-513
[7]
Fransson B, 1985, Dent Mater, V1, P197, DOI 10.1016/S0109-5641(85)80019-1
[8]
Freedman G, 1998, Dent Clin North Am, V42, P683
[9]
MARGINS OF COMPLETE CROWNS - LITERATURE-REVIEW [J].
GARDNER, FM .
JOURNAL OF PROSTHETIC DENTISTRY, 1982, 48 (04) :396-400
[10]
CLINICAL AND SEMIQUANTITATIVE MARGINAL ANALYSIS OF 4 TOOTH-COLORED INLAY SYSTEMS AT 3 YEARS [J].
GLADYS, S ;
VANMEERBEEK, B ;
INOKOSHI, S ;
WILLEMS, G ;
BRAEM, M ;
LAMBRECHTS, P ;
VANHERLE, G .
JOURNAL OF DENTISTRY, 1995, 23 (06) :329-338