The value of positron emission tomography in the clinical evaluation of dementia

被引:12
作者
Gill, SS
Rochon, PA
Guttman, M
Laupacis, A
机构
[1] Baycrest Ctr Geriatr Care, Kunin Lunenfeld Appl Res Unit, Toronto, ON M6A 2E1, Canada
[2] Univ Toronto, Natl Parkinson Fdn Ctr Excellence, Inst Clin Evaluat Sci, Toronto, ON, Canada
[3] Univ Toronto, Natl Parkinson Fdn Ctr Excellence, Dept Med, Toronto, ON, Canada
[4] Univ Toronto, Natl Parkinson Fdn Ctr Excellence, Div Neurol, Toronto, ON, Canada
[5] Univ Toronto, Natl Parkinson Fdn Ctr Excellence, Dept Psychiat, Toronto, ON, Canada
[6] Ctr Addict & Mental Hlth, Toronto, ON, Canada
关键词
Alzheimer's disease; dementia; positron emission tomography;
D O I
10.1046/j.1532-5415.2003.51067.x
中图分类号
R592 [老年病学]; C [社会科学总论];
学科分类号
03 ; 0303 ; 100203 ;
摘要
Positron emission tomography (PET) has been promoted as a means of improving the diagnosis of Alzheimer's disease (AD), but the evidence to support its incremental value is unclear. To assess the evidence regarding the use of PET in the clinical evaluation of AD, a systematic review of the English-language literature indexed in MEDLINE (1975-January 2001), the Cochrane Library (issue 4, 2000), and health technology assessment (HTA) reports was conducted. Articles identified by this review process were graded for methodological and reporting quality using a standardized grading scheme. Sixteen original articles and seven HTA reports were identified. In general, the articles addressed: using PET to differentiate AD from normal aging or non-Alzheimer's dementias, PET imaging compared with single positron emission computed tomography imaging, using PET to predict the progression of dementia, and agreement and reliability in the interpretation of PET images. Serious problems with study design and methodology in all articles were identified. Previous HTA reports have generally recommended that PET not be used in the clinical evaluation of dementia. In conclusion, there is little evidence to support the addition of PET to the routine clinical evaluation of patients with suspected or established dementia. Suggestions for future research in this area are offered.
引用
收藏
页码:258 / 264
页数:7
相关论文
共 31 条
[1]  
ADAMS EJ, 1999, POSITRON EMISSION TO
[2]   Alzheimer disease: Improved visual interpretation of PET images by using three-dimensional stereotaxic surface projections [J].
Burdette, JH ;
Minoshima, S ;
Borght, TV ;
Tran, DD ;
Kuhl, DE .
RADIOLOGY, 1996, 198 (03) :837-843
[3]  
*CAT AG HLTH TECHN, 1993, ASS CLIN PET VAR IND
[4]  
*COUNC MED IM, 1999, FUT POS EM TOM ONT O
[5]   The role of neuroimaging in dementia [J].
DeCarli, C .
CLINICS IN GERIATRIC MEDICINE, 2001, 17 (02) :255-+
[6]  
DELEON MJ, 1983, AM J NEURORADIOL, V4, P568
[7]   POSITRON EMISSION TOMOGRAPHY IN ALZHEIMERS-DISEASE [J].
DUARA, R ;
GRADY, C ;
HAXBY, J ;
SUNDARAM, M ;
CUTLER, NR ;
HESTON, L ;
MOORE, A ;
SCHLAGETER, N ;
LARSON, S ;
RAPOPORT, SI .
NEUROLOGY, 1986, 36 (07) :879-887
[8]   SENSITIVITY AND SPECIFICITY OF POSITRON EMISSION TOMOGRAPHY AND MAGNETIC-RESONANCE-IMAGING STUDIES IN ALZHEIMERS-DISEASE AND MULTI-INFARCT DEMENTIA [J].
DUARA, R ;
BARKER, W ;
LOEWENSTEIN, D ;
PASCAL, S ;
BOWEN, B .
EUROPEAN NEUROLOGY, 1989, 29 :9-15
[9]  
FAZEKAS F, 1989, J NUCL MED, V30, P1607
[10]   CLINICAL-NEUROPATHOLOGICAL CORRELATIONS IN ALZHEIMERS-DISEASE AND RELATED DEMENTIAS [J].
GALASKO, D ;
HANSEN, LA ;
KATZMAN, R ;
WIEDERHOLT, W ;
MASLIAH, E ;
TERRY, R ;
HILL, R ;
LESSIN, P ;
THAL, LJ .
ARCHIVES OF NEUROLOGY, 1994, 51 (09) :888-895