Endotension in an experimental aneurysm model

被引:31
作者
Skillern, CS [1 ]
Stevens, SL [1 ]
Piercy, KT [1 ]
Donnell, RL [1 ]
Freeman, MB [1 ]
Goldman, MH [1 ]
机构
[1] Univ Tennessee, Med Ctr, Dept Surg, Div Vasc Surg, Knoxville, TN 37920 USA
关键词
D O I
10.1067/mva.2002.127520
中图分类号
R61 [外科手术学];
学科分类号
摘要
Purpose: The purpose of this study was to design an experimental model of endotension and to investigate whether attachment site failure without endoleak results in higher aneurysm sac pressure (ASP). Methods: Infrarenal aortic aneurysms were created in canines with an elliptical knitted polyester patch. Pressure transducers were inserted into the aneurysm. Group I (n = 4) underwent endovascular stent graft exclusion of the aneurysm. An attachment site failure was formed in group II (n = 5) before aneurysm exclusion. ASP measurements were obtained for 3 weeks, and the ratio of mean ASP to mean systemic blood pressure (ASP/BP) was calculated. Before explant, norepinephrine was administered and ASPs were recorded at varying systemic pressures. Stent graft cuff exclusion of the attachment site failure was performed in group II. Results. Intraoperative arteriography and duplex ultrasonagraphy did not reveal an endoleak in either group. ASP/BP in group I was 0.39 +/- 0.02 compared with 1.01 +/- 0.02 in group II (P <.001). Mean systemic pressure varied from 55 to 177 mm Hg after norepinephrine administration. Within this interval, ASP/BP was 0.51 +/- 0.10 in group I compared with 0.91 +/- 0.10 in group II (P <.001). ASP/BP before cuff deployment in group II was 0.98 +/- 0.08 compared with 0.46 +/- 0.04 after cuff deployment (P <.001). Conclusion: Systemic pressure is transmitted to the aneurysm sac through an attachment site failure, despite no endoleak, resulting in endotension. Cuff exclusion of the attachment site failure decreases ASP. ASP may help determine the need for future intervention after endovascular aneurysm repair.
引用
收藏
页码:814 / 817
页数:4
相关论文
共 11 条
[1]   Continued sac expansion in the absence of a demonstrable endoleak is an indication for secondary intervention [J].
Fisher, RK ;
Brennan, JA ;
Gilling-Smith, GL ;
Harris, PL .
EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2000, 20 (01) :96-98
[2]  
Gilling-Smith G, 1999, J ENDOVASC SURG, V6, P305, DOI 10.1583/1074-6218(1999)006<0305:EAEARD>2.0.CO
[3]  
2
[4]   Incidence and risk factors of late rupture, conversion, and death after endovascular repair of infrarenal aortic aneurysms: The EUROSTAR experience [J].
Harris, PL ;
Vallabhaneni, SR ;
Desgranges, P ;
Bacquemin, JP ;
van Marrewijk, C ;
Laheij, RJF .
JOURNAL OF VASCULAR SURGERY, 2000, 32 (04) :739-749
[5]   Endoleak after endovascular graft repair of experimental aortic aneurysms: Does coil embolization with angiographic "seal" lower intraaneurysmal pressure? [J].
Marty, B ;
Sanchez, LA ;
Ohki, T ;
Wain, RA ;
Faries, PL ;
Cynamon, J ;
Marin, ML ;
Veith, FJ .
JOURNAL OF VASCULAR SURGERY, 1998, 27 (03) :454-461
[6]   Endoleakage after stent-graft treatment of abdominal aneurysm: Implications on pressure and imaging - an in vitro study [J].
Schurink, GWH ;
Aarts, NJM ;
Wilde, J ;
van Baalen, JM ;
Chuter, TAM ;
Kool, LJ ;
van Bockel, JH .
JOURNAL OF VASCULAR SURGERY, 1998, 28 (02) :234-241
[7]   Experimental study of the influence of endoleak size on pressure in the aneurysm sac and the consequences of thrombosis [J].
Schurink, GWH ;
Aarts, NJM ;
van Baalen, JM ;
Kool, LJS ;
van Bockel, JH .
BRITISH JOURNAL OF SURGERY, 2000, 87 (01) :71-78
[8]  
White GH, 1999, J ENDOVASC SURG, V6, P308, DOI 10.1583/1074-6218(1999)006<0308:EAEFCA>2.0.CO
[9]  
2
[10]   Aneurysm rupture after endovascular repair using the AneuRx stent graft [J].
Zarins, CK ;
White, RA ;
Fogarty, TJ .
JOURNAL OF VASCULAR SURGERY, 2000, 31 (05) :960-970