A simulation study evaluating the performance of high-density electrode arrays on myocardial tissue

被引:13
作者
Eason, JC
Eason, C
Malkin, RA
机构
[1] Univ Vermont, Dept Elect & Comp Engn, Burlington, VT 05405 USA
[2] Univ Memphis, Dept Biomed Engn, Memphis, TN 38152 USA
关键词
cardiac mapping; electrode array; electrode-tissue interface; extracellular potentials; finite elements; propagation model;
D O I
10.1109/10.846683
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Multielectrode arrays used to detect cellular activation have become so dense (electrodes per square millimeter) as to jeopardize the basic assumptions of activation mapping; namely, that electrodes are points adequately separated as to not interfere with the tissue or each other. This paper directly tests these assumptions for high-density electrode arrays. Using a finite element model with modified Fitzhugh-Nagumo kinetics, we represent electrodes as isopotential surfaces of varying widths and spacing ratio (SR) (center-to-center spacing divided by electrode width). We examine the signal strength and ability of a single electrode to detect activation due to a passing wavefront. We find that high-density arrays do not cause significant wavefront curvature or alter activation timing in the underlying tissue. Relationships between signal strength, cross talk, and array design are explained by the interaction of the propagating wavefront and induced sources on the isopotential electrodes. Sensitivity analysis shows that these results may be generalized to a wide range of physiologically relevant designs and applications. We conclude that electrode array designs in which electrode spacing greatly exceeds electrode diameter are overly conservative and that arrays with a SR of less than 2.0 may perform successfully in electrophysiological studies.
引用
收藏
页码:893 / 901
页数:9
相关论文
共 25 条
[1]   EFFICIENT ELECTRODE SPACING FOR EXAMINING SPATIAL-ORGANIZATION DURING VENTRICULAR-FIBRILLATION [J].
BAYLY, PV ;
JOHNSON, EE ;
IDRISS, SF ;
IDEKER, RE ;
SMITH, WM .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1993, 40 (10) :1060-1066
[2]  
Burnett DS., 1987, FINITE ELEM ANAL DES
[3]  
EASON X, 1998, CIRC RES, V83, P1003
[4]  
Efimov IR, 1998, CIRC RES, V82, P918
[5]   Virtual electrode effects in transvenous defibrillation-modulation by structure and interface: Evidence from bidomain simulations and optical mapping [J].
Entcheva, E ;
Eason, J ;
Efimov, IR ;
Cheng, Y ;
Malkin, R ;
Claydon, F .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 1998, 9 (09) :949-961
[6]   Anisotropic activation spread in heart cell monolayers assessed by high-resolution optical mapping - Role of tissue discontinuities [J].
Fast, VG ;
Darrow, BJ ;
Saffitz, JE ;
Kleber, AG .
CIRCULATION RESEARCH, 1996, 79 (01) :115-127
[7]   Spatial changes in transmembrane potential during extracellular electrical shocks in cultured monolayers of neonatal rat ventricular myocytes [J].
Gillis, AM ;
Fast, VG ;
Rohr, S ;
Kleber, AG .
CIRCULATION RESEARCH, 1996, 79 (04) :676-690
[8]  
HENRIQUEZ CS, 1993, CRIT REV BIOMED ENG, V21, P1
[9]   TIME DELAYS IN PROPAGATION OF CARDIAC ACTION-POTENTIAL [J].
ISRAEL, DA ;
EDELL, DJ ;
MARK, RG .
AMERICAN JOURNAL OF PHYSIOLOGY, 1990, 258 (06) :H1906-H1917
[10]  
KNILSEY SB, 1993, CIRC RES, V72, P255