Rejection criteria for open-path Fourier transform infrared spectrometry during continuous atmospheric monitoring

被引:15
作者
Shao, Limin
Pollard, Matthew J.
Griffiths, Peter R. [1 ]
Westermann, Dale T.
Bjorneberg, David L.
机构
[1] Univ Idaho, Dept Chem, Moscow, ID 83844 USA
[2] ARS, USDA, NW Irrigat & Soils Res Lab, Kimberly, ID 83341 USA
关键词
open-path; atmospheric monitoring; FTIR; interferogram rejection;
D O I
10.1016/j.vibspec.2006.06.016
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Over 32,000 interferograms measured during open-path Fourier transform infrared (OP/Fr-IR) measurements at dairy and hog farms were evaluated for anomalies. Five types of anomalies could be distinguished: a reduction in the interferogram intensity because of weather-related optical misalignment; an increase in the amplitude of interferograms measured with too short a path-length that leads to a non-linear detector response; a periodic interference caused by wind-induced vibrations; the presence of spikes in the interferogram; and an increase in the noise level of the interferogram (and hence of the spectrum) because of the effect of electrical interference. Prior to testing for the presence of anomalous data, each interferogram is subjected to a high-pass filter. A noise level index is then calculated from the wings of the interferogram and interferograms are rejected if the value of this parameter is too high. When the criteria developed in this project are applied, OP/Fr-IR spectra may be measured at 1-min intervals over a period of several days. (C) 2006 Published by Elsevier B.V.
引用
收藏
页码:78 / 85
页数:8
相关论文
共 11 条
[1]  
American Society for Testing and Materials ASTM G32, 1998, ANN BOOK ASTM STAND
[2]  
[Anonymous], 1997, ANN BOOK ASTM STAND, DOI [10.1520/F1841-97R05.2, DOI 10.1520/C0349-97]
[3]   NONLINEAR DETECTOR RESPONSE IN FT-IR [J].
CHASE, DB .
APPLIED SPECTROSCOPY, 1984, 38 (04) :491-494
[4]   Multi-pollutant concentration measurements around a concentrated swine production facility using open-path FTIR spectrometry [J].
Childers, JW ;
Thompson, EL ;
Harris, DB ;
Kirchgessner, DA ;
Clayton, M ;
Natschke, DF ;
Phillips, WJ .
ATMOSPHERIC ENVIRONMENT, 2001, 35 (11) :1923-1936
[5]  
GRIFFITHS PR, 1986, FOURIER TRANSFORM IN, P74
[6]   Effects of resolution on quantification in open-path Fourier transform infrared spectrometry under conditions of low detector noise. 2. Partial least squares regression [J].
Hart, BK ;
Berry, RJ ;
Griffiths, PR .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2000, 34 (07) :1346-1351
[7]   Use of partial least squares regression for the multivariate calibration of hazardous air pollutants in open-path FT-IR spectrometry. [J].
Hart, BK ;
Griffiths, PR .
FOURIER TRANSFORM SPECTROSCOPY, 1998, (430) :241-244
[8]   Open-path FT-IR takes the long view [J].
Newman, AR .
ANALYTICAL CHEMISTRY, 1997, 69 (01) :A43-A47
[9]  
Russwum G.M., 2002, HDB VIBRATIONAL SPEC, V2
[10]  
Russwurm G.M., 1997, COMPENDIUM METHODS D