Separation, preconcentration and inductively coupled plasma-mass spectrometric (ICP-MS) determination of thorium(IV), titanium(IV), iron(III), lead(II) and chromium(III) on 2-nitroso-1-naphthol impregnated MCI GEL CHP20P resin

被引:199
作者
Aydin, Funda Armagan [1 ,2 ]
Soylak, Mustafa [1 ]
机构
[1] Erciyes Univ, Fac Art & Sci, Dept Chem, TR-38039 Kayseri, Turkey
[2] Gen Directorate State Hydraul Works, Tech Res & Qual Control Dept, TR-06100 Ankara, Turkey
关键词
MCI GEL CHP20P; 2-Nitroso-1-naphthol; Impregnation; Solid phase extraction; Inductively coupled plasma-mass spectrometry; ATOMIC-ABSORPTION-SPECTROMETRY; SOLID-PHASE EXTRACTION; SURFACTANT-COATED ALUMINA; CLOUD POINT EXTRACTION; NATURAL-WATER SAMPLES; SILICA MEMBRANE DISKS; TRACE-METAL IONS; AMBERLITE XAD-16; CHELATING RESIN; COLUMN PRECONCENTRATION;
D O I
10.1016/j.jhazmat.2009.08.137
中图分类号
X [环境科学、安全科学];
学科分类号
083001 [环境科学];
摘要
A simple and effective method is presented for the separation and preconcentration of Th(IV), Ti(IV), Fe(III), Pb(II) and Cr(III) by solid phase extraction on 2-nitroso-1-naphthol impregnated MCI GEL CHP20P resin prior to their inductively coupled plasma-mass spectrometric determinations. The influence of analytical parameters including pH of the aqueous solution, flow rates of sample and eluent solutions and sample volume on the quantitative recoveries of analyte ions was investigated. Matrix effects caused by the presence of alkali, earth alkali and some metal ions in the analyzed solutions were investigated. The presented solid phase extraction method was applied to BCR-144R Sewage Sludge (domestic origin), BCR-141R Calcareous Loam Soil, NIST 1568a Rice Flour and NIST 1577b Bovine Liver certified reference materials (CRMs) for the determination of analyte ions and the results were in good agreement with the certified values. The separation procedure presented was also applied to the various natural water samples collected from Turkey with satisfactory results. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:669 / 674
页数:6
相关论文
共 54 条
[1]
Afzali D, 2008, J AOAC INT, V91, P1430
[2]
Preconcentration, speciation and determination of ultra trace amounts of mercury by modified octadecyl silica membrane disk/electron beam irradiation and cold vapor atomic absorption spectrometry [J].
Ashkenani, Hamid ;
Dadfarnia, Shayessteh ;
Shabani, Ali Mohammad Haji ;
Jaffari, Abbas Ali ;
Behjat, Abbas .
JOURNAL OF HAZARDOUS MATERIALS, 2009, 161 (01) :276-280
[3]
Avci H, 2008, ASIAN J CHEM, V20, P2827
[4]
Use of Amberlite XAD-2 loaded with 1-(2-pyridylazo)-2-naphthol as a preconcentration system for river water prior to determination of Cu2+, Cd2+ and Pb2+ by flame atomic absorption spectroscopy [J].
Bermejo-Barrera, P ;
Nancy, MA ;
Cristina, DL ;
Adela, BB .
MICROCHIMICA ACTA, 2003, 142 (1-2) :101-108
[5]
Separation of gallium and indium from ores matrix by sorption on Amberlite XAD-2 coated with PAM [J].
Bermejo-Barrera, P ;
Martínez-Alsonso, N ;
Bermejo-Barrera, A .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2001, 369 (02) :191-194
[6]
Cerutti S, 2005, ATOM SPECTROSC, V26, P125
[7]
Ciappini M. C., 2008, APIACTA, V43, P25
[8]
EREN E, 2008, TURKEY J HAZARD MAT, V259, P235
[9]
Farooq A, 2007, MAIN GROUP MET CHEM, V30, P345
[10]
Octadecyl silica membrane disks modified with a new Schiff's base for the preconcentration of lead and copper before their determination in water samples [J].
Ganjali, MR ;
Pourjavid, MR ;
Babaei, LH ;
Salavati-Niasari, M .
ANNALI DI CHIMICA, 2004, 94 (5-6) :447-456