Assessment of visually lossless irreversible image compression: Comparison of three methods by using an image-comparison workstation

被引:81
作者
Slone, RM [1 ]
Foos, DH [1 ]
Whiting, BR [1 ]
Muka, E [1 ]
Rubin, DA [1 ]
Pilgram, TK [1 ]
Kohm, KS [1 ]
Young, SS [1 ]
Ho, P [1 ]
Hendrickson, DD [1 ]
机构
[1] Washington Univ, Sch Med, Edward Mallinckrodt Inst Radiol, Barnes Jewish Hosp, St Louis, MO 63110 USA
关键词
computers; diagnostic aid; data compression; images; artifact; display; processing; picture archiving and communication system (PACS);
D O I
10.1148/radiology.215.2.r00ap47543
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To determine the degree of irreversible image compression detectable in conservative viewing conditions. MATERIALS AND METHODS: An image-comparison workstation, which alternately displayed two registered and magnified versions of an image, was used to study observer detection of image degradation introduced by irreversible compression. Five observers evaluated 20 16-bit posteroanterior digital chest radiographs compressed with Joint Photographic Experts Group (JPEG) or wavelet-based trellis-coded quantization (WTCQ) algorithms at compression ratios of 8:1-128:1 and x2 magnification by using (a) traditional two-alternative forced choice; (b) original-revealed two-alternative forced choice, in which the noncompressed image is identified to the observer; and (c) a resolution-metric method of matching test images to degraded reference images. RESULTS: The visually lossless threshold was between 8:1 and 16:1 for four observers. JPEG compression resulted in performance as good as that with WTCQ compression at these ratios. The original-revealed forced-choice method was faster and as sensitive as the two-alternative forced-choice method. The resolution-metric results were robust and provided information on performance above visually lossless levels. CONCLUSION: The image-comparison workstation is a versatile tool for comparative assessment of image quality. At x2 magnification, images compressed with either JPEG or WTCQ algorithms were indistinguishable from unaltered original images for most observers at compression ratios between 8:1 and 16:1, indicating that 10:1 compression is acceptable for primary image interpretation.
引用
收藏
页码:543 / 553
页数:11
相关论文
共 27 条
[1]   THE EFFECT OF IRREVERSIBLE IMAGE COMPRESSION ON DIAGNOSTIC-ACCURACY IN THORACIC IMAGING [J].
ABERLE, DR ;
GLEESON, F ;
SAYRE, JW ;
BROWN, K ;
BATRA, P ;
YOUNG, DA ;
STEWART, BK ;
HO, BKT ;
HUANG, HK .
INVESTIGATIVE RADIOLOGY, 1993, 28 (05) :398-403
[2]  
Beard D, 1990, J Digit Imaging, V3, P108
[3]   Information and image integration: Project spectrum [J].
Blaine, GJ ;
Jost, RG ;
Martin, L ;
Weiss, DA ;
Lehmann, R ;
Fritz, K .
MEDICAL IMAGING 1998 - PACS DESIGN AND EVALUATION: ENGINEERING AND CLINICAL ISSUES, 1998, 3339 :430-439
[4]   The effects of lossy compression on the detection of subtle pulmonary nodules [J].
Cox, GG ;
Cook, LT ;
Insana, MF ;
McFadden, MA ;
Hall, TJ ;
Harrison, LA ;
Eckard, DA ;
Martin, NL .
MEDICAL PHYSICS, 1996, 23 (01) :127-132
[5]  
Cox JR, 1997, P SOC PHOTO-OPT INS, V3031, P256, DOI 10.1117/12.273903
[7]   IMAGE COMPRESSION THROUGH WAVELET TRANSFORM CODING [J].
DEVORE, RA ;
JAWERTH, B ;
LUCIER, BJ .
IEEE TRANSACTIONS ON INFORMATION THEORY, 1992, 38 (02) :719-746
[8]  
*DIG IM COMM MED, 1996, NEMA STAND PUBL
[9]   Lossy compression using wavelets, block DCT, and lapped orthogonal transforms optimized with a perceptual model [J].
Eckert, MP .
IMAGE DISPLAY - MEDICAL IMAGING 1997, 1997, 3031 :339-350
[10]  
Fleiss JL, 1981, STAT METHODS RATES P