摘要
Ability of a de electrical discharge to control low-velocity airflow along,a flat plate is analyzed. Specifically, the electrodes are flush mounted on the insulating surface of the plate creating a tangential corona discharge at close vicinity of the wall. In this paper, visualizations of the low-velocity airflow (up to 1.4 m/s corresponding to Re = 16 000) along the flat plate are presented. They show that the ionic wind induced by the corona discharge modifies the original airflow considerably, resulting in the airflow reattachment to the wall and reduction of the wake size. Velocity measurements by particle imaging velocimetry and by Pitot tube are conducted in a wind-tunnel loop for higher airflow velocities (up to 11 m/s corresponding to Re = 117 800). Results show that the corona discharge at such high airflow velocities does affect significantly the velocity profile within the viscous boundary layer.
引用
收藏
页码:1478 / 1485
页数:8
相关论文
共 20 条
[1]  
ARTANA G, 2001, 39 AIAA AER C REN NV
[2]  
ARTANA G, 2001, 4 AIAA WEAKL ION GAS
[3]  
BAILEY AG, 1988, ELECTROSTATIC SPRAYI, P38
[4]  
BALLEREAU P, 1980, THESIS U PARIS SUD O
[5]  
BRUSHNELL DM, 1983, AIAA C REN NV
[6]   Modeling of DC corona discharge along an electrically conductive flat plate with gas flow [J].
Colver, GM ;
El-Khabiry, S .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1999, 35 (02) :387-394
[7]  
CORKE TC, 2000, AIAA C DENV CO
[8]   EFFECT OF HUMIDITY ON POSITIVE CORONA DISCHARGE IN A 3-ELECTRODE SYSTEM [J].
FOUAD, L ;
ELHAZEK, S .
JOURNAL OF ELECTROSTATICS, 1995, 35 (01) :21-30
[9]  
KLIBER KG, 1974, J APPL PHYS, V45, P4436
[10]   Influence of a DC corona discharge on the airflow along an inclined flat plate [J].
Léger, L ;
Moreau, E ;
Artana, G ;
Touchard, G .
JOURNAL OF ELECTROSTATICS, 2001, 51 (1-4) :300-306