Automatic determination of aortic compliance with cine-magnetic resonance imaging -: An application of fuzzy logic theory

被引:20
作者
Lalande, A
Van Kien, PK
Salvé, N
Ben Salem, D
Legrand, L
Walker, PM
Wolf, JE
Brunotte, FO
机构
[1] Univ Bourgogne, Fac Med, Biophys Lab, F-21079 Dijon, France
[2] Ctr Hosp Univ Dijon, Ctr Genet, Dijon, France
[3] Ctr Hosp Univ Dijon, Serv Cardiol 2, Dijon, France
[4] Univ Bourgogne, Fac Med, Lab Informat Med, Dijon, France
关键词
aortic compliance; cine-MRI; automatic contour detection; fuzzy logic;
D O I
10.1097/00004424-200212000-00008
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
RATIONALE AND OBJECTIVES. Aortic compliance is defined as the relative change in aortic cross-sectional area divided by the change in arterial pressure. Magnetic resonance imaging (MRI) is a useful imaging modality for the noninvasive evaluation of aortic compliance. However, manual tracing of the aortic contour is subject to important interobserver variations. To estimate the aortic compliance from cine-MRI, a method based on fuzzy logic theory was elaborated. MATERIALS AND METHODS. Seven healthy volunteers and eight patients with Marfan syndrome were examined using an ECG gated cine-MRI sequence. The aorta was imaged in the transverse plane at the level of the pulmonary trunk. A method based on fuzzy logic was developed to automatically detect the aortic contour. RESULTS. Through our robust automatic contouring method, the calculation of aortic cross-sectional areas allows an estimation of the aortic compliance. CONCLUSION. The aortic compliance can be obtained from a fuzzy logic based automatic contouring method, thereby avoiding the important interobserver variation often associated with manual tracing.
引用
收藏
页码:685 / 691
页数:7
相关论文
共 38 条
[1]   ELASTIC PROPERTIES AND WINDKESSEL FUNCTION OF THE HUMAN AORTA [J].
BELZ, GG .
CARDIOVASCULAR DRUGS AND THERAPY, 1995, 9 (01) :73-83
[2]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[3]   Estimation of aortic compliance using magnetic resonance pulse wave velocity measurement [J].
Boese, JM ;
Bock, M ;
Schoenberg, SO ;
Schad, LR .
PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (06) :1703-1713
[4]   Accuracy of arterial pulse-wave velocity measurement using MR [J].
Bolster, BD ;
Atalar, E ;
Hardy, CJ ;
McVeigh, ER .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1998, 8 (04) :878-888
[5]   Total arterial compliance estimated by stroke volume to aortic pulse pressure ratio in humans [J].
Chemla, D ;
Hébert, JL ;
Coirault, C ;
Zamani, K ;
Suard, I ;
Colin, P ;
Lecarpentier, Y .
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 1998, 274 (02) :H500-H505
[6]   Magnetic resonance imaging evaluation of aortic elastic properties as early expression of Marfan syndrome [J].
Fattori, R ;
Reggiani, LB ;
Pepe, G ;
Napoli, G ;
Bnà, C ;
Celletti, F ;
Lovato, L ;
Gavelli, G .
JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2000, 2 (04) :251-256
[7]   AUTOMATED IDENTIFICATION OF LEFT-VENTRICULAR BORDERS FROM SPIN-ECHO MAGNETIC-RESONANCE IMAGES - EXPERIMENTAL AND CLINICAL FEASIBILITY STUDIES [J].
FLEAGLE, SR ;
THEDENS, DR ;
EHRHARDT, JC ;
SCHOLZ, TD ;
SKORTON, DJ .
INVESTIGATIVE RADIOLOGY, 1991, 26 (04) :295-303
[8]   Measurement of regional aortic compliance by MR imaging: A study of reproducibility [J].
Forbat, SM ;
Mohiaddin, RH ;
Yang, GZ ;
Firmin, DN ;
Underwood, SR .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1995, 5 (06) :635-639
[9]   Detection of abnormal aortic elastic properties in asymptomatic patients with Marfan syndrome by combined transoesophageal echocardiography and acoustic quantification [J].
Franke, A ;
Muhler, EG ;
Klues, HG ;
Peters, K ;
Lepper, W ;
vonBernuth, G ;
Hanrath, P .
HEART, 1996, 75 (03) :307-311
[10]   Biophysical properties of the normal-sized aorta in patients with Marfan syndrome: Evaluation with MR flow mapping [J].
Groenink, M ;
de Roos, A ;
Mulder, BJM ;
Verbeeten, B ;
Timmermans, J ;
Zwinderman, AH ;
Spaan, JAE ;
van der Wall, EE .
RADIOLOGY, 2001, 219 (02) :535-540