A computerized method of visual acuity testing: Adaptation of the early treatment of diabetic retinopathy study testing protocol

被引:476
作者
Beck, RW
Moke, PS
Turpin, AH
Ferris, FL
Sangiovanni, JP
Johnson, CA
Birch, EE
Chandler, DL
Cox, TA
Blair, RC
Kraker, RT
机构
[1] Jaeb Ctr Hlth Res, Tampa, FL 33613 USA
[2] Curtin Univ, Bentley, WA, Australia
[3] NEI, Div Epidemiol & Clin Res, NIH, Bethesda, MD 20892 USA
[4] Devers Eye Inst, Discoveries Sight Res Labs, Portland, OR USA
[5] Retina Fdn SW, Dallas, TX USA
关键词
D O I
10.1016/S0002-9394(02)01825-1
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To develop a computerized method of visual acuity testing for clinical research as an alternative to the standard Early Treatment for Diabetic Retinopathy Study (ETDRS) testing protocol, and to evaluate its test-retest reliability and concordance with standard ETDRS testing. DESIGN: Test-retest reliability study. METHODS: Multicenter setting of a study population of 265 patients at three clinical sites. Visual acuity was measured with both the electronic visual acuity testing algorithm (E-ETDRS) and standard ETDRS protocol (S-ETDRS) twice on one eye of each patient. E-ETDRS testing was conducted using the electronic visual acuity tester (EVA), which utilizes a programmed Palm (Palm, Inc, Santa Clara, California, USA) hand-held device communicating with a personal computer and 17-inch monitor at a test distance of 3 meters. RESULTS: For the E-ETDRS protocol, test-retest reliability was high (r = 0.99; with 89% and 98% of retests within 0.1 logMAR and 0.2 logMAR of initial tests, respectively) and comparable with that of S,ETDRS testing (r = 0.99; with 87% and 98% of retests within 0.1 logMAR and 0.2 logMAR of initial test, respectively). The E-ETDRS and S-ETDRS scores were highly correlated (r = 0.96 for initial tests and r = 0.97 for repeat tests). Based on estimates of 95% confidence intervals, a change in visual acuity of 0.2 logMAR (10 letters) from a baseline level is unlikely to be related to measurement variability using either the E,ETDRS or the S-ETDRS visual acuity testing protocol. CONCLUSIONS: The E-ETDRS protocol has high test-retest reliability and good concordance with S-ETDRS testing. The computerized method has advantages over the S-ETDRS testing in electronically capturing the data for each tested letter, requiring only a single distance for testing from 20/12 to 20/800, potentially reducing testing time, and potentially decreasing technician-related bias. (C) 2003 by Elsevier Science Inc. All rights reserved.
引用
收藏
页码:194 / 205
页数:12
相关论文
共 17 条