Differentiation of hepatocellular carcinoma and hepatic metastasis from cysts and hemangiomas with calculated T2 relaxation times and the T1/T2 relaxation times ratio

被引:46
作者
Farraher, Steven W.
Jara, Hernan
Chang, Kevin J.
Ozonoff, Al
Soto, Jorge A.
机构
[1] Boston Univ, Med Ctr, Dept Radiol, Boston, MA 02118 USA
[2] Boston Univ, Sch Publ Hlth, Boston, MA USA
关键词
liver neoplasms; liver magnetic resonance (MR) image processing; magnetic resonance (MR) tissue characterization; liver; abdominal MR;
D O I
10.1002/jmri.20758
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To determine the diagnostic capability of the T1 and T2 relaxation times and the T1/T2 relaxation times ratio generated with the mixed turbo spin echo (mixed-TSE) pulse sequence, in order to discriminate between hepatocellular carcinoma (HCC)/metastases and hemangiomas/cysts. Materials and Methods: A retrospective review of 36 MR examinations implementing the mixed-TSE pulse sequence demonstrated 70 focal hepatic lesions. Quantitative MR algorithms were used to generate T1 and T2 relaxation times, and the T1/T2 relaxation times ratio for each lesion. A two-sample t-test compared mean T1 and T2 relaxation times, and the T1/T2 relaxation times ratio, by lesion type: carcinoma/metastases and hemangiomas/cysts. Sensitivity and specificity for discriminating carcinoma/metastases from hemangiomas/cysts with T2 relaxation time thresholds of 112 and 125 msec, as well as a ratio of T1/T2 relaxation times of 5.8, were calculated. Results: Using a T2 relaxation time threshold of 112 msec, 92% sensitivity and 100% specificity discriminating cysts/hemangiomas from HCC/liver metastasis was demonstrated. With a threshold of 125 msec, 96% sensitivity and 98% specificity was demonstrated. There was no correlation between calculated T1 relaxation times and type of lesion. Using a T1/T2 relaxation times ratio of 5.8, 100% sensitivity and specificity were demonstrated. Conclusion: Although there is high sensitivity and specificity associated with the use of T2 relaxation times alone to discriminate carcinoma/metastases from hemangiomas/cysts, using the T1/T2 relaxation times ratio threshold of 5.8 allowed proper classification of all lesions.
引用
收藏
页码:1333 / 1341
页数:9
相关论文
共 35 条
[1]   Single-shot T2-weighted MR imaging of the upper abdomen: Preliminary experience with double-echo HASTE technique [J].
Bosmans, H ;
VanHoe, L ;
Gryspeerdt, S ;
Kiefer, B ;
VanSteenbergen, W ;
Baert, AL ;
Marchal, G .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1997, 169 (05) :1291-1293
[2]   T2-WEIGHTED MR-IMAGING OF THE ABDOMEN - FAST SPIN-ECHO VS CONVENTIONAL SPIN-ECHO SEQUENCES [J].
CATASCA, JV ;
MIROWITZ, SA .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1994, 162 (01) :61-67
[3]   SMALL HEPATOCELLULAR-CARCINOMA VERSUS SMALL CAVERNOUS HEMANGIOMA - DIFFERENTIATION WITH MR IMAGING AT 2.0 T [J].
CHOI, BI ;
HAN, MC ;
KIM, CW .
RADIOLOGY, 1990, 176 (01) :103-106
[4]   Discrimination of benign from malignant hepatic lesions based on their T2-relaxation times calculated from moderately T2-weighted turbo SE sequence [J].
Cieszanowski, A ;
Szeszkowski, W ;
Golebiowski, M ;
Bielecki, DK ;
Grodzicki, M ;
Pruszynski, B .
EUROPEAN RADIOLOGY, 2002, 12 (09) :2273-2279
[5]   MR imaging relaxation times of abdominal and pelvic tissues measured in vivo at 3.0 T: Preliminary results [J].
de Bazelaire, CMJ ;
Duhamel, GD ;
Rofsky, NM ;
Alsop, DC .
RADIOLOGY, 2004, 230 (03) :652-659
[6]   RLSQ - T1, T2, AND RHO-CALCULATIONS, COMBINING RATIOS AND LEAST-SQUARES [J].
DENKLEEF, JJEI ;
CUPPEN, JJM .
MAGNETIC RESONANCE IN MEDICINE, 1987, 5 (06) :513-524
[7]   HEPATIC-TUMORS - QUANTITATIVE TISSUE CHARACTERIZATION WITH MR IMAGING [J].
EGGLIN, TK ;
RUMMENY, E ;
STARK, DD ;
WITTENBERG, J ;
SAINI, S ;
FERRUCCI, JT .
RADIOLOGY, 1990, 176 (01) :107-110
[8]   Signal characteristics of focal liver lesions on double echo T2-weighted conventional spin echo MRI: Observer performance versus quantitative measurements of T2 relaxation times [J].
Fenlon, HM ;
Tello, R ;
deCarvalho, VLS ;
Yucel, EK .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2000, 24 (02) :204-211
[9]   HEPATIC HEMANGIOMA - DYNAMIC BOLUS CT [J].
FREENY, PC ;
MARKS, WM .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1986, 147 (04) :711-719
[10]   PATTERNS OF CONTRAST ENHANCEMENT OF BENIGN AND MALIGNANT HEPATIC NEOPLASMS DURING BOLUS DYNAMIC AND DELAYED CT [J].
FREENY, PC ;
MARKS, WM .
RADIOLOGY, 1986, 160 (03) :613-618